E6582175
I-2
9
Table 1 EMC standards
Category
Subcategory
Product
standards
Test standard
Emission
Radiated noise
IEC 61800-3
CISPR11(EN55011)
Conducted noise
CISPR11(EN55011)
Immunity
Static discharge
IEC61000-4-2
Radioactive radio-frequency
magnetic contactor field
IEC61000-4-3
First transient burst
IEC61000-4-4
Surge
IEC61000-4-5
Radio-frequency
induction/transmission interference
IEC61000-4-6
Voltage dip/Interruption of power
IEC61000-4-11
9.1.2
Measures to satisfy the EMC Directive
This subsection explains what measures must be taken to satisfy the EMC Directive.
(1) Insert an EMC filter on the input side of the inverter to reduce conducted noise and radiated noise from input
cables.
Single-phase 240V class and three-phase 500V class inverters are equipped with an EMC filter.
Table 2 Combinations of inverter and EMC filter
Three-phase 240 V class
Combination of inverter and filter
Inverter type
Conducted noise
IEC61800-3, category C1
(Motor wiring length of 1m or less)
Conducted noise
IEC61800-3, category C2
(Motor wiring length of 5m or less)
VFS15-2004PM-W1
EMFS11-2007AZ
VFS15-2007PM-W1
EMFS11-2007AZ
VFS15-2015PM-W1
EMFS11-4015BZ
VFS15-2022PM-W1
EMFS11-4015BZ
VFS15-2037PM-W1
EMFS11-4025CZ
VFS15-2055PM-W1
EMFS11-4047DZ
VFS15-2075PM-W1
EMFS11-4047DZ
VFS15-2110PM-W1
EMFS11-2083EZ
VFS15-2150PM-W1
EMFS11-2083EZ