84
P9 ASD Installation and Operation Manual
Preset Speed 1
Program
Frequency
Preset Speeds
Up to fifteen (15) output frequency values that fall within the
Lower-Limit
and
the
Upper-Limit
range may be programmed into the ASD and output as a
Preset Speed
. This parameter assigns an output frequency to binary number
0001 and is identified as
Preset Speed 1
. The binary number is applied to
S1
–
S4
of the
Terminal Board
to output the
Preset Speed
.
Perform the following setup to allow the system to receive
Preset Speed
control input at the
S1 – S4
terminals:
1.
Program
Fundamental
Standard Mode Selection
Command Mode
Selection
Terminal Block
.
2.
Program
Terminal
Input Terminals
S1
(set to
Preset Speed 1
;
LSB of 4-bit count). Repeat for
S2
–
S4
(MSB of 4-bit count) as
Preset
Speed 2
–
4
, respectively (all
Normally Open
).
3.
Program
Frequency
Preset Speeds
Preset Speed
1
(set an output
frequency as
Preset Speed 1
; repeat for
Preset Speeds 2
–
15
as required).
4.
Program
Pattern Run
Operation Mode
Preset Speed Operation
Mode
Enabled/Disabled
.
Select
Enabled
to use the direction, accel/decel, and torque settings of the
Preset Speed
being run. The torque settings used will be as defined in
–
and as selected via the associated discrete input terminals
V/f
Switching 1
and
2
in
.
Select
Disabled
to use the speed setting only of the
Preset Speed
being run.
5.
Place the system in the
Hand
mode (Hand/Auto LED Off).
6.
Provide a
Run
command (connect F and/or R to CC).
Connect
S1
to
CC
to run
Preset Speed 1
(
S1
to
CC
= 0001 binary).
With
S1
–
S4
configured to output
Preset Speeds
–
), 0001 – 1111
may be applied to
S1 – S4
of the
Terminal Board
to run the associated
Preset
Speed
. If bidirectional operation is required,
F
and
R
must be connected to
CC
,
and
Preset Speed Operation Mode
must be set to
Enabled
at
With
S1
being the least significant bit of a binary count, the
S1 – S4
settings
will produce the programmed speed settings as indicated in the
Preset Speed
Truth Table
to the right.
Preset Speeds
are also used in the
Pattern Run
mode.
Direct Access Number — F018
Parameter Type —
Numerical
Factory Default —
0.0
Changeable During Run —
Yes
Minimum — Lower-Limit Freq. (
)
Maximum — Upper-Limit Freq. (
Units — Hz
Preset Speed Truth Table
Preset Speed 2
Program
Frequency
Preset Speeds
This parameter assigns an output frequency to binary number 0010 and is
identified as
Preset Speed 2
. The binary number is applied to
S1
–
S4
of the
Terminal Board
to output the
Preset Speed
.
See
for additional information on this parameter.
Direct Access Number — F019
Parameter Type —
Numerical
Factory Default —
0.0
Changeable During Run —
Yes
Minimum — Lower-Limit Freq. (
)
Maximum — Upper-Limit Freq. (
Units — Hz
eset Speed 1
Preset
S4
MSB
S3
S2
S1
LSB
Output
1
0
0
0
1
2
0
0
1
0
3
0
0
1
1
4
0
1
0
0
5
0
1
0
1
6
0
1
1
0
7
0
1
1
1
8
1
0
0
0
9
1
0
0
1
10
1
0
1
0
11
1
0
1
1
12
1
1
0
0
13
1
1
0
1
14
1
1
1
0
15
1
1
1
1
Note:
1 = Terminal connected to
CC
.
eset Speed 2
Содержание P9
Страница 1: ...TM P9 ASD Install Op Manual TOSHIBA P9 ASD INSTALLATION OPERATION MANUAL DN 64054 004 February 2013 ...
Страница 2: ......
Страница 3: ...Document Number 64054 004 February 2013 P9 ASD Installation Operation Manual TM ...
Страница 4: ......
Страница 280: ...270 P9 ASD Installation and Operation Manual Figure 38 See Tables 17 and 18 for Actual Dimensions ...
Страница 281: ...P9 ASD Installation and Operation Manual 271 Figure 39 See Tables 17 and 18 for Actual Dimensions ...
Страница 282: ...272 P9 ASD Installation and Operation Manual Figure 40 See Tables 17 and 18 for Actual Dimensions ...
Страница 285: ...P9 ASD Installation and Operation Manual 275 Figure 43 See Table 18 for the associated device Dimensions are in in cm ...
Страница 304: ...294 P9 ASD Installation and Operation Manual W W T3 16 Warranty Card 2 W Phase Over Current 265 ...
Страница 305: ......