P9 ASD Installation and Operation Manual
237
Input Function Target 2
Program
My Function
My Function Unit 7
This parameter plays a role in the setup of the
My Function
feature by
selecting the functionality of the programmable
Input Function Target 2
terminal.
This setting assigns the function of the programmable
Input Function Target 2
terminal to any one of the user-selectable functions listed in
, or
See
for additional information on this parameter.
Direct Access Number — F955
Parameter Type —
Selection List
Factory Default —
0 (Disabled)
Changeable During Run —
Yes
Input Function Command 2
Program
My Function
My Function Unit 7
This parameter is used to assign a user-selected logical operator to two user-
selected
Input Function Target
variables, enable a counter/timer function, or
perform a hold/reset function.
lists the available selections. Their use and selection
requirements are described in an example at
.
Direct Access Number — F956
Parameter Type —
Selection List
Factory Default —
0 (NOP)
Input Function Target 3
Program
My Function
My Function Unit 7
This parameter plays a role in the setup of the
My Function
feature by
selecting the functionality of the programmable
Input Function Target 3
terminal.
This setting assigns the function of the programmable
Input Function Target 3
terminal to any one of the user-selectable functions listed in
, or
See
for additional information on this parameter.
Direct Access Number — F957
Parameter Type —
Selection List
Factory Default —
0 (Disabled)
Changeable During Run —
Yes
Output Function Assigned
Program
My Function
My Function Unit 7
This parameter plays a role in the setup of the
My Function
feature by
selecting the functionality of the
Output Function Assigned
terminal.
This setting assigns the function of the programmable
Output Function
Assigned
data location to one of the functions listed in the
Input Setting
field
of
.
Settings:
0 – 3099
See the
My Function Instruction Manual
(P/N E6581335) and
for
additional information on this parameter.
Direct Access Number — F958
Parameter Type —
Selection List
Factory Default —
0 (Disabled)
Changeable During Run —
Yes
Содержание P9
Страница 1: ...TM P9 ASD Install Op Manual TOSHIBA P9 ASD INSTALLATION OPERATION MANUAL DN 64054 004 February 2013 ...
Страница 2: ......
Страница 3: ...Document Number 64054 004 February 2013 P9 ASD Installation Operation Manual TM ...
Страница 4: ......
Страница 280: ...270 P9 ASD Installation and Operation Manual Figure 38 See Tables 17 and 18 for Actual Dimensions ...
Страница 281: ...P9 ASD Installation and Operation Manual 271 Figure 39 See Tables 17 and 18 for Actual Dimensions ...
Страница 282: ...272 P9 ASD Installation and Operation Manual Figure 40 See Tables 17 and 18 for Actual Dimensions ...
Страница 285: ...P9 ASD Installation and Operation Manual 275 Figure 43 See Table 18 for the associated device Dimensions are in in cm ...
Страница 304: ...294 P9 ASD Installation and Operation Manual W W T3 16 Warranty Card 2 W Phase Over Current 265 ...
Страница 305: ......