220
P9 ASD Installation and Operation Manual
Communications Option (DeviceNet/Profibus) Setting 2
Program
Communications
Communication Settings
While using the DeviceNet/Profibus communications protocol, parameters
allow the user to select the ASD memory location that holds the
Command/Frequency/Monitoring instructions to be applied to the ASD for
Communications Option Settings 2
–
7
, respectively.
See the
DeviceNet Option Instruction Manual
(P/N 58683) for additional
information on this parameter.
Settings:
0 — Disabled
1 — FA06 (ALCAN Command 1)
2 — FA23 (ALCAN Command 2)
3 — FA07 (ALCAN Frequency Command, 0.01 Hz)
4 — FA33 (Torque Command, 0.01%)
5 — FA50 (Terminal Output)
6 — FA51 (Analog Output Data from Comm. [FM])
7 — FA52 (Analog Output Data from Comm. [AM])
8 —
(Stall Prevention Level, %)
9 —
(Power Running Torque Limit 1 Level, 0.01%)
10 —
(Regen. Braking Torque Limit 1 Level, 0.01%)
(Speed Loop Proportional Gain)
12 —
(Speed Loop Stabilization Coefficient)
Direct Access Number — F831
Parameter Type —
Selection List
Factory Default —
0000h
Changeable During Run —
Yes
Communications Option (DeviceNet/Profibus) Setting 3
Program
Communications
Communication Settings
See
for information on this parameter.
Direct Access Number — F832
Parameter Type —
Selection List
Factory Default —
0000h
Changeable During Run —
Yes
Communications Option (DeviceNet/Profibus) Setting 4
Program
Communications
Communication Settings
See
for information on this parameter.
Direct Access Number — F833
Parameter Type —
Selection List
Factory Default —
0000h
Changeable During Run —
Yes
Communications Option (DeviceNet/Profibus) Setting 5
Program
Communications
Communication Settings
See
for information on this parameter.
Direct Access Number — F834
Parameter Type —
Selection List
Factory Default —
0000h
Changeable During Run —
Yes
Communications Option (DeviceNet/Profibus) Setting 6
Program
Communications
Communication Settings
See
for information on this parameter.
Direct Access Number — F835
Parameter Type —
Selection List
Factory Default —
0000h
Changeable During Run —
Yes
Communications Option (DeviceNet/Profibus) Setting 7
Program
Communications
Communication Settings
See
for information on this parameter.
Direct Access Number — F836
Parameter Type —
Selection List
Factory Default —
0000h
Changeable During Run —
Yes
Содержание P9
Страница 1: ...TM P9 ASD Install Op Manual TOSHIBA P9 ASD INSTALLATION OPERATION MANUAL DN 64054 004 February 2013 ...
Страница 2: ......
Страница 3: ...Document Number 64054 004 February 2013 P9 ASD Installation Operation Manual TM ...
Страница 4: ......
Страница 280: ...270 P9 ASD Installation and Operation Manual Figure 38 See Tables 17 and 18 for Actual Dimensions ...
Страница 281: ...P9 ASD Installation and Operation Manual 271 Figure 39 See Tables 17 and 18 for Actual Dimensions ...
Страница 282: ...272 P9 ASD Installation and Operation Manual Figure 40 See Tables 17 and 18 for Actual Dimensions ...
Страница 285: ...P9 ASD Installation and Operation Manual 275 Figure 43 See Table 18 for the associated device Dimensions are in in cm ...
Страница 304: ...294 P9 ASD Installation and Operation Manual W W T3 16 Warranty Card 2 W Phase Over Current 265 ...
Страница 305: ......