P9 ASD Installation and Operation Manual
133
Preset Speed 9
Program
Frequency
Preset Speeds
This parameter assigns an output frequency to binary number 1001 and is
identified as
Preset Speed 9
. The binary number is applied to
S1
–
S4
of the
Terminal Board
to output the
Preset Speed
.
See
for additional information on this parameter.
Direct Access Number — F288
Parameter Type —
Numerical
Factory Default —
0.0
Changeable During Run —
Yes
Minimum — Lower-Limit Freq. (
)
Maximum — Upper-Limit Freq. (
Units — Hz
Preset Speed 10
Program
Frequency
Preset Speeds
This parameter assigns an output frequency to binary number 1010 and is
identified as
Preset Speed 10
. The binary number is applied to
S1
–
S4
of the
Terminal Board
to output the
Preset Speed
.
See
for additional information on this parameter.
Direct Access Number — F289
Parameter Type —
Numerical
Factory Default —
0.00
Changeable During Run —
Yes
Minimum — Lower-Limit Freq. (
)
Maximum — Upper-Limit Freq. (
Units — Hz
Preset Speed 11
Program
Frequency
Preset Speeds
This parameter assigns an output frequency to binary number 1011 and is
identified as
Preset Speed 11
. The binary number is applied to
S1
–
S4
of the
Terminal Board
to output the
Preset Speed
.
See
for additional information on this parameter.
Direct Access Number — F290
Parameter Type —
Numerical
Factory Default —
0.00
Changeable During Run —
Yes
Minimum — Lower-Limit Freq. (
)
Maximum — Upper-Limit Freq. (
Units — Hz
Preset Speed 12
Program
Frequency
Preset Speeds
This parameter assigns an output frequency to binary number 1100 and is
identified as
Preset Speed 12
. The binary number is applied to
S1
–
S4
of the
Terminal Board
to output the
Preset Speed
.
See
for additional information on this parameter.
Direct Access Number — F291
Parameter Type —
Numerical
Factory Default —
0.00
Changeable During Run —
Yes
Minimum — Lower-Limit Freq. (
)
Maximum — Upper-Limit Freq. (
Units — Hz
Preset Speed 13
Program
Frequency
Preset Speeds
This parameter assigns an output frequency to binary number 1101 and is
identified as
Preset Speed 13
. The binary number is applied to
S1
–
S4
of the
Terminal Board
to output the
Preset Speed
.
See
for additional information on this parameter.
Direct Access Number — F292
Parameter Type —
Numerical
Factory Default —
0.00
Changeable During Run —
Yes
Minimum — Lower-Limit Freq. (
)
Maximum — Upper-Limit Freq. (
Units — Hz
Preset Speed 14
Program
Frequency
Preset Speeds
This parameter assigns an output frequency to binary number 1110 and is
identified as
Preset Speed 14
. The binary number is applied to
S1
–
S4
of the
Terminal Board
to output the
Preset Speed
.
See
for additional information on this parameter.
Direct Access Number — F293
Parameter Type —
Numerical
Factory Default —
0.00
Changeable During Run —
Yes
Minimum — Lower-Limit Freq. (
)
Maximum — Upper-Limit Freq. (
Units — Hz
Содержание P9
Страница 1: ...TM P9 ASD Install Op Manual TOSHIBA P9 ASD INSTALLATION OPERATION MANUAL DN 64054 004 February 2013 ...
Страница 2: ......
Страница 3: ...Document Number 64054 004 February 2013 P9 ASD Installation Operation Manual TM ...
Страница 4: ......
Страница 280: ...270 P9 ASD Installation and Operation Manual Figure 38 See Tables 17 and 18 for Actual Dimensions ...
Страница 281: ...P9 ASD Installation and Operation Manual 271 Figure 39 See Tables 17 and 18 for Actual Dimensions ...
Страница 282: ...272 P9 ASD Installation and Operation Manual Figure 40 See Tables 17 and 18 for Actual Dimensions ...
Страница 285: ...P9 ASD Installation and Operation Manual 275 Figure 43 See Table 18 for the associated device Dimensions are in in cm ...
Страница 304: ...294 P9 ASD Installation and Operation Manual W W T3 16 Warranty Card 2 W Phase Over Current 265 ...
Страница 305: ......