LubriMist
®
Model IVT
Oil Mist Generating System
Installation and Operating Manual
Page 87
of 256
Reading Alarm And Control Set Points
In addition to being able to read existing operating conditions, the factory set alarm and control
set points can also be prompted and displayed. The operating variables that are monitored have
preset alarm set points for high and low limits. The air / oil heater and optional air pre-heater also
have a control function to control air temperature.
The systems control and alarm set point values are listed in the table below. Note that the main
oil mist generator reservoir has a non-adjustable low oil level switch that provides an alarm when
the oil level falls below the set level, however there is no programmable set point feature for this
alarm.
Factory Default Set point Values
Set Point Variable
Imperial
Units
Metric Units
Air Temperature - Control Set-point
120
°
F
49
°
C
Air Temperature - High Alarm Set-point
140
°
F
60
°
C
Air Temperature - Low Alarm Set-point
100
°
F
38
°
C
Air / Oil Heater - High Temperature Cutout Set-point
150
°
F
66
°
C
Supply Air Pressure - High Alarm Set-point
150 PSI
10.3 BAR
Supply Air Pressure - Low Alarm Set-point
25 PSI
1.7 BAR
Regulated Air Pressure - High Alarm Set-point
65 PSI
4.5 BAR
Regulated Air Pressure - Low Alarm Set-point
10 PSI
0.7 BAR
Supply Oil Pressure - High Alarm Set-point
150 PSI
10.3 BAR
Supply Oil Pressure - Low Alarm Set-point
10 PSI
0.7 BAR
Mist Pressure - High Alarm Set-point
30 In. H
2
0
75 m BAR
Mist Pressure - Low Alarm Set-point
10 In. H
2
0
25 m BAR
Mist Density - High Alarm Set-point
90 %
90 %
Mist Density - Low Alarm Set-point
10 %
10 %
Bulk Oil Reservoir Temperature - High Alarm Set-point
160
°
F
71
°
C
Bulk Oil Reservoir Temperature - Low Alarm Set-point
10
°
F
-12
°
C
Bulk Oil Reservoir Level - High Alarm Set-point
75 Gallons
284 Liter
Bulk Oil Reservoir Level - Low Alarm Set-point
10 Gallons
38 Liter
Air Pre-heater Temperature - Enable Set-point
40
°
F
5
°
C
Air Pre-heater Temperature - Control Set-point
60
°
F
16
°
C
Air Pre-heater Temperature - High Alarm Set-point
80
°
F
27
°
C
Air Pre-heater Temperature - Low Alarm Set-point
30
°
F
-1
°
C
Air Pre-heater – High Temperature Cutout Set-point
100
°
F
38
°
C
The factory default control and alarm set points for the operating functions listed above can be
prompted and displayed for review. The first step is to identify which function the controller is to
display. To view the variable control and alarm set point values follow these steps.
1. Press the [SET] key.
2. Press the variable <FUNCTION> key that is to be viewed.
3. Use the [ENTER] key to toggle through the control-high-low -cutout set point values for each
operating variable. Note that as the set point variables are scrolled, a message is displayed
to alert the operator that set point adjustments are not allowed.
4. After the last set point value is displayed for the specified operating variable, press [ENTER
]
to return the screen to normal view.
The controller continues to monitor and control normally while doing set point queries.
To change the factory default control and alarm set point values see
Programming User
Established Alarm And Control Set Points
in the section titled OPERATING GUIDE of this
manual.
Содержание LubriMist IVT
Страница 22: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 22 of 256...
Страница 63: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 63 of 256...
Страница 81: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 81 of 256 OPERATING GUIDE...
Страница 148: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page148 of 256...
Страница 149: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page149 of 256 CONTROLLING THE MIST...
Страница 152: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page152 of 256...
Страница 161: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page161 of 256 TROUBLE SHOOTING GUIDE...
Страница 204: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 204 of 256 IVT Front Cabinet Door...
Страница 208: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 208 of 256 IVT Cabinet Rear...
Страница 236: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 236 of 256 Air Supply Components...
Страница 245: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 245 of 256 Air Supply Components...