Model Code Designation Key
LubriMist® Model IVT
Oil Mist Generator
Option Description
Option Code
Description
Electrical Standard
C
ATEX II 3G Ex ic nA nC db eb mb IIC T4 Gc
IECEx Ex ic nA nC db eb mb IIC T4 Gc
N
NEC CLASS 1 DIV 2 GROUP B/C/D T4 (Class I, Zone 2, Group IIB = H2)
Inlet Power
A
115 VAC 50/60 HZ SINGLE PHASE & IMPERIAL MEASURING UNITS (NOTE 3)
S
230 VAC 50/60 HZ SINGLE PHASE & IMPERIAL MEASURING UNITS
M
115 VAC 50/60 HZ SINGLE PHASE & METRIC MEASURING UNITS (NOTE 3)
B
230 VAC 50/60 HZ SINGLE PHASE & METRIC MEASURING UNITS
Labeling
E
ENGLISH and SPANISH
X
NOT LISTED - CONSULT FACTORY FOR AVAILABILITY
Oil Mist Reclamation
X
NONE
A
NEMA MOTOR: 115/230 VAC 60 HZ SINGLE PHASE; EXPLOSION PROOF
CLASS 1 GROUP C/D T3C; (NOTE 1)
B
MOTOR: 230/460 VAC 50/60 HZ 3 PHASE; EXPLOSION PROOF
CLASS 1 GROUP C/D T3C (NOTE 1)
C
MOTOR: 230VAC 50 HZ 1 PHASE;
EX d e IIC T4 Gb IP56 - ZONE 2 (NOTE 2)
D
MOTOR: 380/400/415 VAC 50HZ 3 PHASE
EX d e IIC T4 Gb IP56 - ZONE 2 (NOTE 2)
E
NEMA MOTOR: 575 VAC 50/60 HZ 3 PHASE; EXPLOSION PROOF
CLASS 1 GROUP C/D T3C (NOTE 1)
F
MOTOR: 250 VAC 50 HZ 1 PHASE; EXPLOSION PROOF
CLASS 1GROUP C/D T3C (NOTE 1)
Cabinet Accessories
X
NONE
C
NEC - WARM AMBIENT OPTION (CABINET COOLING) (NOTE 5)
P
NEC & ATEX - AIR PURGING (ROTOMETER) (NOTE 7)
H
NEC - COLD AMBIENT - AIR PRE-HEATING ONLY(NOTE 6)
J
NEC - BOTH WARM & COLD AMBIENTS
S
NEC COLD AMBIENT – AIR PREHEATING & CABINET HEATING (NOTE 6)
W
ATEX - WARM AMBIENT - CABINET COOLING (NOTE 5)
Q
ATEX - COLD AMBIENT - AIR PRE-HEATING & CABINET HEATING (NOTE 6)
K
ATEX - BOTH WARM & COLD AMBIENT OPTIONS
Special
NON-REQUIRED FIELD.
CONSULT FACTORY IF FIELD INCLUDES ENTRY
1
AUTO BULK FILL
2
SS T304 SUNSHADE
MODEL CODE
IVT _ _ _ _ _
NOTES:
1) FOR NEC CONSTRUCTION ONLY.
2) FOR ATEX CONSTRUCTION ONLY
3) AIR PRE-HEATING OPTION IS NOT AVAILABLE WITH 115VAC ATEX CONSTRUCTION
4) IF OIL MIST RECLAMATION OPTION IS SELECTED, IVT WILL ONLY BE SUITABLE FOR CLASS 1 DIV. 2
GROUP C/D. TEMPERATURE CODE RATING ON THE MOTOR WILL DICTATE THE TEMPERATURE CODE
RATING FOR THE IVT.
5) REQUIRED WHEN MAXIMUM AMBIENT TEMPERATURE EXCEEDS 104F (40C).
6) REQUIRED WHEN MINIMUM AMBIENT TEMPERATURE FALLS BELOW 15F (-10C).
7) REQUIRED FOR HIGHLY CORROSIVE OR HUMID OPERATING CONDITIONS
Содержание LubriMist IVT
Страница 22: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 22 of 256...
Страница 63: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 63 of 256...
Страница 81: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 81 of 256 OPERATING GUIDE...
Страница 148: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page148 of 256...
Страница 149: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page149 of 256 CONTROLLING THE MIST...
Страница 152: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page152 of 256...
Страница 161: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page161 of 256 TROUBLE SHOOTING GUIDE...
Страница 204: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 204 of 256 IVT Front Cabinet Door...
Страница 208: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 208 of 256 IVT Cabinet Rear...
Страница 236: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 236 of 256 Air Supply Components...
Страница 245: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 245 of 256 Air Supply Components...