Switching From The Auxiliary Oil Mist Generator To The Main Oil Mist Generator.
Once the main oil mist generator has been serviced or repaired, it should be put back in service.
1) Turn OFF the electrical power to the auxiliary oil mist generator The electrical power switch is
located in the top of the operator panel
a) Separate power switches are provided for the main and auxiliary oil mist generators in
NEC configured units. The auxiliary oil mist generator switch is located on the right side.
Move the switch to the OFF position.
b) For ATEX configured units, power is supplied through a three-position selector switch. To
turn power OFF to the auxiliary unit move the selector switch to the center position.( I
O
II
)
2) Turn OFF the air supply to the auxiliary oil mist generator.
a) Adjust the air pressure regulator to the closed position. Turning the adjustment knob on
the air pressure regulator in the full counter clockwise position places it in the closed
position. The mist pressure will bleed to zero.
b) Close the air supply block valve to the auxiliary oil mist generator
3) Commission the main oil mist generator as described in the section titled COMMISSIONING
in this manual.
Mist Outlet Switching Valve
The Model IVT Oil Mist Generator console is equipped with a pneumatically operated switching
valve that automatically connects the mist outlet of either the main or auxiliary oil mist generator
to the mist outlet pipe. When the air pressure is being supplied to the main oil mist generator the
mist outlet is open to the main oil mist generator and closed to the auxiliary unit. When the
auxiliary oil mist generator is operating the mist outlet valve automatically opens to the discharge
of the auxiliary oil mist generator and blocks the outlet to the main oil mist generator. If air is
being supplied to both the main and the auxiliary units, both outlet connections are open and both
units discharge mist into the distribution header system.
NOTICE:
The main and auxiliary oil mist generators should not be operated in
parallel. The fail open design is intended to safe guard against
unintentional improper switching between the main and auxiliary oil
mist generator. Failure to properly follow instructions may result in a
high mist pressure condition.
Содержание LubriMist IVT
Страница 22: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 22 of 256...
Страница 63: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 63 of 256...
Страница 81: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 81 of 256 OPERATING GUIDE...
Страница 148: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page148 of 256...
Страница 149: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page149 of 256 CONTROLLING THE MIST...
Страница 152: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page152 of 256...
Страница 161: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page161 of 256 TROUBLE SHOOTING GUIDE...
Страница 204: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 204 of 256 IVT Front Cabinet Door...
Страница 208: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 208 of 256 IVT Cabinet Rear...
Страница 236: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 236 of 256 Air Supply Components...
Страница 245: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 245 of 256 Air Supply Components...