LubriMist
®
Model IVT
Oil Mist Generating System
Installation and Operating Manual
Page 122
of 256
Connection Detail Screen
figure 2
•
Hardware Flow Control (leave blank).
•
Click OK, the Modscan screen will appear and begin polling.
•
To stop polling click the disconnect button.
See figure 3
The Modscan screen can be customized in many different configurations, but for the purpose of
this document, only 2 will be covered.
1. Breakdown of each Function Code and it’s HEX Addresses.
2. Viewing the IVT’s values in real time.
Before number 1 can be analyzed, below is a brief description on the Function Codes and the
HEX Addresses.
Function Codes
There are the four Function Codes that are utilized by the IVT controller program. In that, there
are 52 different parameters in the IVT program that can be read by Modscan. Each of the 52
parameters is broken down into their specific Function Codes (01---04).
Function Code description
Explanation
01 Coil Status
has 6 Digital outputs
02 Input Status
has 9 Digital inputs
03 Holding Register
has 24 Setpoints
04 Input register
has 13 Analog inputs
Содержание LubriMist IVT
Страница 22: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 22 of 256...
Страница 63: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 63 of 256...
Страница 81: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 81 of 256 OPERATING GUIDE...
Страница 148: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page148 of 256...
Страница 149: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page149 of 256 CONTROLLING THE MIST...
Страница 152: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page152 of 256...
Страница 161: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page161 of 256 TROUBLE SHOOTING GUIDE...
Страница 204: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 204 of 256 IVT Front Cabinet Door...
Страница 208: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 208 of 256 IVT Cabinet Rear...
Страница 236: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 236 of 256 Air Supply Components...
Страница 245: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 245 of 256 Air Supply Components...