The IVT Cabinet Heating system (ATEX) is designed to insure that during cold ambient
conditions, the internal cabinet temperature is maintained above -20
°
C (-4
°
F). This option is
REQUIRED where the ambient temperature drops below -20
°
C (-4
°
F) to maintain the ATEX
certification. See page 15 for more information regarding permissible ambient temperatures.
During startup and commissioning where the ambient temperature is below -20
°
C (-4
°
F ) the
cabinet heater system is energized prior to start up. Startup is delayed until the cabinet
temperature exceeds -20
°
C (-4
°
F). The internal cabinet temperature is monitored by use of a
temperature gauge located on the rear of the IVT cabinet.
Two radiators (heaters) warm the internal cabinet spaces; one is located in the mechanical
compartment and the other inside of the operator interface compartment. Each has an integral
thermostat to control the cabinet internal temperature. Thermostats turn the heaters ON at 10
°
C
(50
°
F) and OFF at 18C (65
°
F). The IVT Oil Mist Generator Cabinet Heating system for the ATEX
construction includes two enclosure radiators (heaters) with thermostats, wire terminal enclosure
an air temperature gauge and a power disconnect switch. The IVT cabinet enclosure is insulated
to retain radiated heat.
When the IVT Oil Mist Generator is equipped at the factory with the Cabinet Heating system, no
additional user connections or installation is required.
2
G 1
3 4
6 7
5
8 9 10 11
Cold Ambient Option (Cabinet Heating) - ATEX constructions
Cabinet Heater
with Thermostat
(Operator interface
compartment)
Air Temperature Gauge
Cabinet Heater with
Thermostat
(Mechanical compartment)
Power
Disconnect
Switch
Содержание LubriMist IVT
Страница 22: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 22 of 256...
Страница 63: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 63 of 256...
Страница 81: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 81 of 256 OPERATING GUIDE...
Страница 148: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page148 of 256...
Страница 149: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page149 of 256 CONTROLLING THE MIST...
Страница 152: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page152 of 256...
Страница 161: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page161 of 256 TROUBLE SHOOTING GUIDE...
Страница 204: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 204 of 256 IVT Front Cabinet Door...
Страница 208: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 208 of 256 IVT Cabinet Rear...
Страница 236: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 236 of 256 Air Supply Components...
Страница 245: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 245 of 256 Air Supply Components...