LubriMist
®
Model IVT
Oil Mist Generating System
Installation and Operating Manual
Page 37
of 256
Oil Mist Reclamation
The Oil Mist Reclamation option is used when LubriMist
Closed Loop Oil Mist systems are
being installed. LubriMist
Closed Loop Oil Mist Systems uses the same principles to apply oil
mist for machinery lubrication as non-closed loop oil mist systems. However when closed loop
systems are installed, after the oil mist has been applied, the oil is continually reclaimed for
reapplication to the serviced rotating machinery.
As the oil mist flows through the rotating equipment bearings and bearing housings, a part of the
oil mist coalesces into liquid oil. A lesser amount of oil remains suspended in the air as it vents
from the bearing housing. This is often referred to as Stray Mist. User equipment items are
equipped with oil collection containers to collect the liquid oil that is manually pumped into the
return mist header. The stray mist is collected into a return mist header as it vents from the
bearing housing. The return mist header is connected to the Oil Mist Reclamation Unit.
An oil over flow connection is located on the right side of the reservoir. This connection allows oil
to be drained away should the reservoir be overfilled. It is located above the high-level switch
position.
The Oil Mist Reclamation unit is a self-contained unit that mounts onto the rear of the IVT Oil Mist
Generator cabinet. The returning stray mist is stripped of its oil by an electric motor driven rotating
coalescer. The returning air is vented from the unit to atmosphere. The coalesced oil is collected
in an integral receiving reservoir. A pneumatic driven transfer pump transfers the liquid oil to the
IVT bulk oil reservoir for reuse. The reservoir is equipped with a liquid level gauge to monitor the
oil level in the reservoir. A bulls-eye sight glass is located at the reservoir bottom to check for
contamination. A high-level alarm switch interlocks with the controller in the IVT main oil mist
generator to provide a system alarm. A separate output signal is provided to interlock with the
motor driver control circuit.
NOTE:
SEPARATE MOTOR DRIVER STARTER AND CONTROL CIRCUITRY ARE TO BE
PROVIDED AND INSTALLED BY THE USER.
Mist Outlet
Connection
2 In 150 # RF
Enclosure Contains
Pump Controls
Air Vent to
Atmosphere
High Level
Alarm Switch
Centrifugal
Coalescer w/
Motor Driver
Oil Level Gauge
Bulls Eye Sight
Mist Return
Connection
2-1/2 In 150 # RF
Over Flow
Connection.
Low Point Drain
IVT Oil Mist
Generator
Содержание LubriMist IVT
Страница 22: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 22 of 256...
Страница 63: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 63 of 256...
Страница 81: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 81 of 256 OPERATING GUIDE...
Страница 148: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page148 of 256...
Страница 149: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page149 of 256 CONTROLLING THE MIST...
Страница 152: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page152 of 256...
Страница 161: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page161 of 256 TROUBLE SHOOTING GUIDE...
Страница 204: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 204 of 256 IVT Front Cabinet Door...
Страница 208: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 208 of 256 IVT Cabinet Rear...
Страница 236: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 236 of 256 Air Supply Components...
Страница 245: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 245 of 256 Air Supply Components...