Air Pre-heater
When installed, the Air Preheating option is an integral part of the Model IVT Oil Mist Generator
and it is automatically controlled by the IVT solid-state control system. No additional user actions
are required to start or commission the Air Pre-heater.
Cabinet Heating System
The IVT Oil Mist Generator cabinet heating system uses the radiant heaters located in the
operator interface compartment and the mechanical compartment. See page 41 or 43 for a full
description. This option is included where the IVT is installed in conditions that are outside of the
standard permissible operating ambient of –20C< AMBIENT < +40C. The permissible operating
ambient for equipment including this option is –40C< AMBIENT < +40C. The IVT Oil Mist
Generator should not be energized if the ambient conditions are outside of these permissible
ambient temperature restrictions.
To commission the cabinet heating system:
A. Locate the proper power switch located on the rear of IVT cabinet. Turn the electrical power
switch to the ON position. If the temperature inside of the cabinet is less than 10
°
C(50
°
F), the
heaters will energize and begin warming the cabinet interior.
B. Find the thermometer that is located on the rear of the IVT cabinet and check the
temperature inside of the cabinet. If the temperature reading is <-20
°
C (-4
°
F), allow the
cabinet heating system to warm the internal cabinet ambient temperature to at least >-20
°
C
before energizing the IVT Oil Mist Generator.
C. When the temperature inside of the cabinet has been heated to at least <-20
°
C (-4
°
F), the
IVT oil mist generator may be started. See
Starting The Model IVT Oil Mist Generator.
D. Ensure that the IVT Oil Mist Generator cabinet doors are closed and that the door latch is
secured in the closed position.
NOTICE:
Do not energize the IVT main or auxiliary oil
mist generator prior to consulting and following
these instructions on starting the IVT Oil Mist
Generator Cabinet Heating System
Use the
thermometer to
monitor the cabinet
temperature.
Turn the power
switch to the ON
position to
energize the
Cabinet Heating
System
Use the
thermometer to
monitor the cabinet
temperature.
Turn the power
switch to the ON
position to
energize the
Cabinet Heating
System
NEC Construction
ATEX Construction
Содержание LubriMist IVT
Страница 22: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 22 of 256...
Страница 63: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 63 of 256...
Страница 81: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 81 of 256 OPERATING GUIDE...
Страница 148: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page148 of 256...
Страница 149: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page149 of 256 CONTROLLING THE MIST...
Страница 152: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page152 of 256...
Страница 161: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page161 of 256 TROUBLE SHOOTING GUIDE...
Страница 204: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 204 of 256 IVT Front Cabinet Door...
Страница 208: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 208 of 256 IVT Cabinet Rear...
Страница 236: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 236 of 256 Air Supply Components...
Страница 245: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 245 of 256 Air Supply Components...