Logged Alarm and Fault Messages.
The following table lists the alarm and fault messages that are logged into the Event Log. Fault
screens have a higher priority than the run-time screen sequence. Alarms and faults are
chronologically displayed. The run-time screen sequence is restarted only after all fault conditions
are gone. However, key sequence functionality is still maintained to allow the operator to change
parameters as needed. If more than one fault is present, the [Clear] key is used to scroll between
faults.
All Event/Fault Events are logged in the Event and Data Logs except for attempted set point
changes when the Restoring Default Settings option is disabled. When the Restoring Default
Settings option is disabled, attempted set point changes are only displayed and not logged. See
the section titled Communication And Option Feature Set-Up -
Step 6a. (
)
Event
Display (Top Line)
Display (Bottom Line)
Mist Head Air Temperature High Alarm
High Air Temp
Mist Head Air Temperature Low Alarm
Low Air Temp
Mist Head High Air Temperature Alarm
High Air Cutoff
Air Temperature
Supply Air Pressure High Alarm
High Supply
Pressure
Supply Air Pressure Low Alarm
Low Supply
Pressure
Regulated Air Pressure High Alarm
High Regulated
Pressure
Regulated Air Pressure Low Alarm
Low Regulated
Pressure
Supply Oil Pressure High Alarm
High Oil Supply
Pressure
Supply Oil Pressure Low Alarm
Low Oil Supply
Pressure
Mist Pressure High Alarm
High Mist
Pressure
Mist Pressure Low Alarm
Low Mist
Pressure
Mist Density High Alarm
High Mist
Density
Mist Density Low Alarm
Low Mist
Density
Bulk Oil Reserve Temperature High Alarm
High Oil Temp
Bulk Oil Reserve Temperature Low Alarm
Low Oil Temp
Bulk Oil Reserve Oil Level High Alarm
High Oil Level
Bulk Tank Level
Bulk Oil Reserve Oil Level Low Alarm
Low Oil Level
Bulk Tank Level
PreHeater Air Temperature High Alarm
High Air Pre-Htr
Air Temperature
PreHeater Air Temperature Low Alarm
Low Air Pre-Htr
Air Temperature
PreHeater High Air Temperature Cutout
Hi PreHtr Cutoff
Air Temperature
Demist Tank High Oil Level Switch
High Oil Level
in De-Mist Tank
Mist Generation Tank Low Level Switch
Low Oil Level
Mist Tank Level
Mist Generating Tank Fill Timeout (1)
Mist Tank Taking
Too Long to Fill
Bad Parameter Setpoint
BAD SETPOINT
VALUE, Corrected
Bulk Oil Solenoid Output Failure
Digital Output
#1 Failure
Status Light Relay Output Failure
Digital Output
#2 Failure
Demister Remote Signal Failure
Digital Output
#3 Failure
Air PreHeater Relay Failure
Digital Output
#4 Failure
Air/Oil Heater Relay Failure
Digital Output
#5 Failure
Air Pump Solenoid Failure
Digital Output
#6 Failure
Internal Failure
Internal Failure
#1
Attempted Set Point Change With Option
Disabled
(
)
No Set Point
Changes Allowed
Содержание LubriMist IVT
Страница 22: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 22 of 256...
Страница 63: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 63 of 256...
Страница 81: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 81 of 256 OPERATING GUIDE...
Страница 148: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page148 of 256...
Страница 149: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page149 of 256 CONTROLLING THE MIST...
Страница 152: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page152 of 256...
Страница 161: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page161 of 256 TROUBLE SHOOTING GUIDE...
Страница 204: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 204 of 256 IVT Front Cabinet Door...
Страница 208: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 208 of 256 IVT Cabinet Rear...
Страница 236: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 236 of 256 Air Supply Components...
Страница 245: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 245 of 256 Air Supply Components...