LubriMist
®
Model IVT
Oil Mist Generating System
Installation and Operating Manual
Page 170
of 256
LOW SUPPLY
PRESSURE
Supply Air
Pressure to IVT
is below Low
Alarm Setting
(25PSI –
1.7BAR)
1. Check supply air pressure at the source, compare to IVT supply pressure
reading. To obtain the Supply Air Pressure reading at the IVT, press
Sup Air
Pres
key.
2. If the IVT supply air pressure reading is lower than the pressure reading at the air
source, check for any shut-off valves installed within the supply airline to the IVT.
Confirm these valves are in the full open position.
3. Check air filter element F-1. A dirty or clogged filter element will result in a
difference in pressure readings from the air source to the IVT. Change filter
element if necessary. CFH-RS part no. 77780124.
4. Increase supply air pressure at the source above Low Alarm Setting (25PSI –
1.7BAR).
HIGH SUPPLY
PRESSURE
Supply Air
Pressure to IVT
is above High
Alarm Setting
(150PSI –
10.3BAR)
1. Check supply air pressure at the source, compare to IVT supply pressure
reading. To obtain the Supply Air Pressure reading at the IVT, press
Sup Air
Pres
key.
2. Reduce supply air pressure at the source below High Alarm Setting (150PSI –
10.3BAR).
HIGH AIR
CUTOFF AIR
TEMPERATURE
Heated Air
Temperature is
above High
Cutoff Alarm
Setting
(150
°
F - 65
°
C)
Note:
High Air
Cutoff alarm is
designed to act
as a failsafe
feature for the
Air Heater
Element. The
temperature
sensor that
controls the high
air cutoff alarm
is separate from
the sensor used
to control air
temperature.
1. Confirm that the Air Heater Set temperature (120
°
F - 49
°
C) is below high air
cutoff alarm setting (150
°
F - 65
°
C). See the IVT Operating Instructions for
instructions on how to program user specified alarm and control set point values.
Note whether customer assigned values have been programmed to the replace
the factory values. To check air heater high cutoff temperature press key
combination
Set
,
Air Temp.
Press the
Enter
key three times to view high cutoff
alarm setting. Press
Clear
key to return to normal operating mode.
2. Press
Air Temp
key. If temperature measurement is low (90
°
F - 100
°
F), the
sensor TE-2 that controls air temperature is failing and should be replaced. CFH-
RS part number 77700941.
3. Check the operation of the Air heater solid state relay SSR-1. Open AC electrical
enclosure, and observe the LED located on the SSR-1. The LED indicates the
operating status of relay. When LED is ON the air heater element is energized.
When LED is OFF the air heater element is de-energized. Confirm LED is OFF
when air temperature at or above control set point.
If the air temperature is above the control set point and the relay SSR-1 is ON,
replace the relay. CFH-RS part number 77780152.
4. If repair is not possible, switch mist generation to Auxiliary. See procedure
located on interior of IVT cabinet door.
Содержание LubriMist IVT
Страница 22: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 22 of 256...
Страница 63: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 63 of 256...
Страница 81: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 81 of 256 OPERATING GUIDE...
Страница 148: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page148 of 256...
Страница 149: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page149 of 256 CONTROLLING THE MIST...
Страница 152: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page152 of 256...
Страница 161: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page161 of 256 TROUBLE SHOOTING GUIDE...
Страница 204: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 204 of 256 IVT Front Cabinet Door...
Страница 208: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 208 of 256 IVT Cabinet Rear...
Страница 236: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 236 of 256 Air Supply Components...
Страница 245: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 245 of 256 Air Supply Components...