3. The OIL FLOW VALVE controls oil mist density (oil/air ratio). Its normal position is fully
closed. By turning it counter-clockwise (opening the bypass) the mist density can be reduced
when leaner density oil mist is desired. It should not be opened more than three turns.
Adjustments to the oil flow valve do not affect oil mist pressure. The oil flow valve is located
on the front of the mist generating head body. Separate mist generating heads are provided
for the main and the auxiliary oil mist generators.
4. The AIR BY-PASS VALVE controls mist pressure without effecting oil output. Its normal
position is fully closed, but by turning it counter clockwise more air will be added to the oil
mist leaving the generator. This essentially dilutes the air / oil ratio by adding more air.
Without reducing the regulated air pressure setting, adjusting the air by-pass valve increases
mist pressure and reduces the oil/air ratio. Velocity of mist through the distribution lines and
reclassifiers will also increase when this valve is opened. The air by-pass valve is located on
the right of the mist generating head body. Separate mist generating heads are provided for
the main and the auxiliary oil mist generators
NOTICE:
The oil / air ratio or mist density is reduced by opening the air by-pass
valve. However, oil output is not affected.
NOTICE:
The oil/air ratio or mist density is also dependent on the
characteristics of the oil, oil temperature and supply air temperature.
Density decreases with lower temperatures and higher oil viscosity.
Air By-Pass Valve
Oil Flow Valve
Содержание LubriMist IVT
Страница 22: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 22 of 256...
Страница 63: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 63 of 256...
Страница 81: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 81 of 256 OPERATING GUIDE...
Страница 148: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page148 of 256...
Страница 149: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page149 of 256 CONTROLLING THE MIST...
Страница 152: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page152 of 256...
Страница 161: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page161 of 256 TROUBLE SHOOTING GUIDE...
Страница 204: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 204 of 256 IVT Front Cabinet Door...
Страница 208: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 208 of 256 IVT Cabinet Rear...
Страница 236: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 236 of 256 Air Supply Components...
Страница 245: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 245 of 256 Air Supply Components...