LubriMist
®
Model IVT
Oil Mist Generating System
Installation and Operating Manual
Page 174
of 256
HIGH AIR PRE-
HTR AIR
TEMPERATURE
Heated Pre-
Heater Air
Temperature is
above High
Alarm Setting
(80
°
F - 27
°
C)
1. A High Air Temperature alarm can occur if the inlet air temperature is warmer that
the PreHeater High Air Temperature alarm setting. Press the key combination
Set
– Set – Air Temp
to view the inlet temperature of Supply Air. This temperature
must be below the High Alarm Setting.
2. Press the key combination
Set – Set – Pre Heater
to view the pre heater
temperature setting. Confirm that the temperature is below the High Alarm Setting.
Determine if customer assigned values have been installed to replace factory
values: To check air pre-heater high alarm temperature setting, press key
combination
Set
,
Pre Heater.
Press the
Enter
key once to view high alarm setting.
Press
Clear
key to return to normal operating mode.
3. Check the operation of the Air Pre-heater solid state relay SSR-2. Open AC
electrical enclosure, and observe the green LED located on the SSR-2. The LED
indicates the operating status of relay. When LED is ON the air heater element is
energized. Confirm that the LED is OFF when air temperature is at or above the
control set point. Replace the SSR-2 relay if the green LED remains ON. CFH-RS
part number 77780152.
HIGH PREHTR
CUTOFF AIR
TEMPERATURE
Heated Pre-
Heater Air
Temperature is
above High
Cutoff Alarm
Setting
(100
°
F - 38
°
C)
1. Press the key sequence
Set – Set – Pre Heater
to view pre heater temperature.
Confirm that the air pre-heater set temperature (60
°
F - 16
°
C) is below the high air
pre-heater cutoff alarm setting (100
°
F - 38
°
C).
Determine if customer assigned values have been installed to replace factory
values: To check air pre-heater high cutoff temperature setting press key
combination
Set
,
PreHeater.
Press the
Enter
key three times to view high cutoff
alarm setting. Press
Clear
key to return to normal operating mode.
2. Press the key sequence
Set – Set – Pre Heater
to view the pre heater
temperature. If temperature measurement is low (30
°
F - 40
°
F), the sensor TE-7
that controls air temperature is failing and should be replaced. (CFH-RS part
number- 77700941).
3. Check the operation of Air Pre-heater solid state relay SSR-2. Open AC electrical
enclosure, and observe the green LED located on the SSR-2. The LED indicates
the operating status of relay. When LED is ON the Air Pre-heater element is
energized. When LED is OFF the air heater element is de-energized. Confirm that
the LED is OFF when the air Pre-heater temperature is at or above the control set
point.
If the air temperature is above the control set point and the relay SSR-2 is ON,
replace the relay. (CFH-RS part number 77780152).
Содержание LubriMist IVT
Страница 22: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 22 of 256...
Страница 63: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 63 of 256...
Страница 81: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 81 of 256 OPERATING GUIDE...
Страница 148: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page148 of 256...
Страница 149: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page149 of 256 CONTROLLING THE MIST...
Страница 152: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page152 of 256...
Страница 161: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page161 of 256 TROUBLE SHOOTING GUIDE...
Страница 204: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 204 of 256 IVT Front Cabinet Door...
Страница 208: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 208 of 256 IVT Cabinet Rear...
Страница 236: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 236 of 256 Air Supply Components...
Страница 245: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 245 of 256 Air Supply Components...