Tag Detail for ATEX Model IVT
LubriMist® IVT Oil Mist Generators manufactured compliant with the ATEX Directive
Data Ref.
Description
Example
Model Code
Per Cust. P.O. & CFH-RS Job Order
See ”
LubriMist®
Model IVT Model Code Designation
Key
”_____________________________
IVT-CBEXX
Serial No.
Unique Serial Numbers are to be issued to each machinery item. The CFH-RS Sales Order
Number is used as serial number prefix, and is followed with a designation for mist flow capacity
specific to the machine being manufactured. The last designation differentiates multiple
machinery’s sold under the same sales order
Sales Order Number
Mist Generating Capacity
060 = 60 Bearing Inch
213 = 213 Bearing Inch
475 = 475 Bearing Inch
933 = 933 Bearing Inch
Item X of Y quantity produced on S.O.
!!!!!!
-
!!!
-
!!
Series No.
Indicates Model Series that the machinery is manufactured. Series numbers are maintained
through revision log. When an Engineering Change is made to the product, those changes are
recorded as a change in Series Number.
This manual is for equipment entering the market as Series 201 A______ (October 2007)
201 A
Volts AC
Machinery is available for connection to either 115 VAC or 230 VAC electrical power. Purchaser
specifies the electrical power requirement. Reference ”LubriMist®
Model IVT Model Code
Designations
”
For 115 VAC power___________________________
For 230 VAC power___________________________
κ
NOTE: Ratings do not include electric motor drivers for “Oil Mist Reclamation” option.
115 VAC
230 VAC
Power
Maximum operating power requirement at the specified voltage with the power selector switch
in the “MAIN” oil mist generator position. (The selector switch allows only the “MAIN” or
“SPARE” oil mist generator to be energized at any given time.
Machinery for use at 115 VAC___________________
Machinery for use at 230 VAC___________________
“AIR PREHEATER and CABINET RADIATORS” option is available for 230 VAC models only.
Reference ”LubriMist®
Model IVT Model Code Designations
”
Machinery with “AIR PREHEATER and CABINET
RADIATORS” option - 230 VAC_________________
κ
NOTE: Ratings do not include electric motor drivers for “Oil Mist Reclamation” option.
8.1 AMP
4.1 AMP
9.0 AMP
Содержание LubriMist IVT
Страница 22: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 22 of 256...
Страница 63: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 63 of 256...
Страница 81: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 81 of 256 OPERATING GUIDE...
Страница 148: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page148 of 256...
Страница 149: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page149 of 256 CONTROLLING THE MIST...
Страница 152: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page152 of 256...
Страница 161: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page161 of 256 TROUBLE SHOOTING GUIDE...
Страница 204: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 204 of 256 IVT Front Cabinet Door...
Страница 208: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 208 of 256 IVT Cabinet Rear...
Страница 236: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 236 of 256 Air Supply Components...
Страница 245: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 245 of 256 Air Supply Components...