Cold Ambient Option (Air Preheating and Cabinet Heating) for ATEX constructions
The Cold Ambient Option (Air Preheating and Cabinet Heating) option for ATEX constructions is
recommended when the IVT Oil Mist Generator is installed in geographical locations where the
minimum ambient temperature falls below -10
°
C (15
°
F). This option is REQUIRED where the
ambient temperature drops below -20
°
C (-4
°
F) to maintain the ATEX certification. See page 15
for more information regarding permissible ambient temperatures.
The IVT Air Pre-heater system is designed to insure that during cold ambient conditions, proper
air and oil temperatures are maintained at the oil mist generator. The pre-heater is installed in the
incoming air supply. A sensor at the inlet of the heater senses the inlet air temperature. When the
inlet air temperature falls below 5
°
C (40
°
F), the pre-heater is activated. The discharge
temperature from the pre-heater is supplied to the mist head and air/oil heater at a controlled
16
°
C (60
°
F). A second sensor provides heater control and high-low alarm input signals. A third
sensor is used for high temperature heater cutout. The IVT cabinet enclosure is insulated to
retain radiated heat from the air pre-heater and discharge tubing.
When the IVT Oil Mist Generator is equipped at the factory with the air preheating system, no
additional user connections or installation is required.
Inlet Air
Connection
Inlet Air Temperature
Sensor
Heater Control And Cutout
Sensors Are Located In The
Heater Discharge
Air Preheater
Содержание LubriMist IVT
Страница 22: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 22 of 256...
Страница 63: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 63 of 256...
Страница 81: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 81 of 256 OPERATING GUIDE...
Страница 148: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page148 of 256...
Страница 149: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page149 of 256 CONTROLLING THE MIST...
Страница 152: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page152 of 256...
Страница 161: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page161 of 256 TROUBLE SHOOTING GUIDE...
Страница 204: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 204 of 256 IVT Front Cabinet Door...
Страница 208: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 208 of 256 IVT Cabinet Rear...
Страница 236: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 236 of 256 Air Supply Components...
Страница 245: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 245 of 256 Air Supply Components...