![RelaDyne LubriMist IVT Скачать руководство пользователя страница 163](http://html1.mh-extra.com/html/reladyne/lubrimist-ivt/lubrimist-ivt_installation-and-operating-manual_1435628163.webp)
LubriMist
®
Model IVT
Oil Mist Generating System
Installation and Operating Manual
Page 163
of 256
Main Unit
ALARM
MESSAGE /
PROBLEM
SOLUTION
LOW MIST
DENSITY
Oil Mist Density
is below Low
Alarm Setting –
Oil Mist quality
has been
compromised.
(10%)
1. Turn mist inspection valve. Visually inspect oil mist quality.
2. Check oil level in mist tank. Confirm Oil Supply Level alarm on front of keypad is
not in active. Verify that the operating oil level is in the normal operating range.
Loss of oil results in loss of oil mist production.
3. Press
Air Temp
key. Confirm air temperature is at control set point (120
°
F -
49
°
C).
If customer assigned values replace factory values: To check control setting
press key combination
Set
,
Air Temp
.
When finished, press the
Clear
key to
return to normal operating mode.
Note:
Decline in Air Temperature will cause the oil viscosity to increase resulting
in a decrease in mist production.
4. Confirm mist head
oil flow valve
has not been adjusted further than 3 turns.
See mist head adjustment screw locations below. Closing the oil flow valve
increases the oil mist output.
Note:
Excessive adjustment to this valve may compromise the oil mist heads
ability to produce quality oil mist.
5. Confirm mist head
air bypass valve
is not over adjusted.
Note:
Excessive adjustment to this valve may over dilute the oil mist with clean
air. Closing the air by-pass valve decreases dilution. Note that adjustments using
the air bypass valve varies mist pressure.
6. Check the oil suction screen for obstruction.
•
Switch to Auxiliary Unit. See instructions located on interior of IVT cabinet
door.
•
Open the left IVT cabinet door. Locate oil suction screen holder on the side
of the mist head. Remove the oil suction screen and clean thoroughly,
reinstall when through.
•
Switch mist generation back to main oil mist generator.
Mist Head Front View Mist Head Right Side View
Suction Screen
Holder
Oil
Flow
Valve
Air
Bypass
Valve
Содержание LubriMist IVT
Страница 22: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 22 of 256...
Страница 63: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 63 of 256...
Страница 81: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 81 of 256 OPERATING GUIDE...
Страница 148: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page148 of 256...
Страница 149: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page149 of 256 CONTROLLING THE MIST...
Страница 152: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page152 of 256...
Страница 161: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page161 of 256 TROUBLE SHOOTING GUIDE...
Страница 204: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 204 of 256 IVT Front Cabinet Door...
Страница 208: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 208 of 256 IVT Cabinet Rear...
Страница 236: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 236 of 256 Air Supply Components...
Страница 245: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 245 of 256 Air Supply Components...