![RelaDyne LubriMist IVT Скачать руководство пользователя страница 134](http://html1.mh-extra.com/html/reladyne/lubrimist-ivt/lubrimist-ivt_installation-and-operating-manual_1435628134.webp)
LubriMist
®
Model IVT
Oil Mist Generating System
Installation and Operating Manual
Page 134
of 256
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
S
V
14
V
13
V
12
V
11
V
10
V
9
V
8
V
7
V
6
V
5
V
4
V
3
V
2
V
1
V
0
V
0
= Least significant bit (LSB) of 15-bit integer value
V
14
= Most significant bit (MSB) of 15-bit integer value
S = Sign bit
These values are transmitted as “twos-complement” integer numbers. This is a standard method
used in computers to represent signed integers. The following table shows how common values
would be represented in twos-complement form.
Signed Decimal
Number
16-bit Twos-Complement Representation
Binary
Decimal
Hexadecimal
-32,768
1000000000000000
32768
8000
-32,767
1000000000000001
32769
8001
-1
1111111111111111
65535
FFFF
0
0000000000000000
0
0000
1
0000000000000001
1
0001
32,766
0111111111111110
32766
7FFE
32767
0111111111111111
32767
7FFF
Although this representation may appear strange at first, it is useful and numerically correct
because simple addition and subtraction yield correct results and it is the most commonly used
format for that reason.
The actual values transmitted for a given analog input or set point are an exact replica of what is
seen on the control panel in the selected units (English or metric)
with an implied decimal point
where applicable. For example, those values with two digit positions to the right of the decimal
point would be transmitted as a numeric value of one hundred times (100x) the reading seen on
the control panel. So the value 123.45 would be transmitted as 12,345 and the host software will
need to scale accordingly. Note that this only affects those data values representing metric units
of Bars such as supply air pressure, regulated air pressure and supply oil pressure and their
related high and low alarm set points. It does not apply to any values when using English units
since all are displayed with no digits to the right of the decimal point.
Содержание LubriMist IVT
Страница 22: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 22 of 256...
Страница 63: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 63 of 256...
Страница 81: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 81 of 256 OPERATING GUIDE...
Страница 148: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page148 of 256...
Страница 149: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page149 of 256 CONTROLLING THE MIST...
Страница 152: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page152 of 256...
Страница 161: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page161 of 256 TROUBLE SHOOTING GUIDE...
Страница 204: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 204 of 256 IVT Front Cabinet Door...
Страница 208: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 208 of 256 IVT Cabinet Rear...
Страница 236: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 236 of 256 Air Supply Components...
Страница 245: ...LubriMist Model IVT Oil Mist Generating System Installation and Operating Manual Page 245 of 256 Air Supply Components...