CDMA2000 Measurements
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
818
User Manual 1173.9511.02 ─ 11
READ:CDMA:MEAS<i>:MEValuation:TRACe:CDE:ISIGnal:MAXimum?
READ:CDMA:MEAS<i>:MEValuation:TRACe:CDE:QSIGnal:CURRent?
READ:CDMA:MEAS<i>:MEValuation:TRACe:CDE:QSIGnal:AVERage?
READ:CDMA:MEAS<i>:MEValuation:TRACe:CDE:QSIGnal:MAXimum?
Returns the values of the code domain error (CDE) I-Signal and Q-Signal traces. The
results of the current, average and maximum traces can be retrieved.
The values described below are returned by
FETCh
and
READ
commands.
CALCulate
commands return limit check results instead, one value for each result listed below.
Return values:
<Reliability>
<CDEcode0> ...
<CDEcodeSF>
The number of results corresponds to the selected spreading
factor (
). E.g. 16 results for SF16.
Range:
-70 dB to 0 dB
Default unit: dB
Example:
See
Multi Evaluation: Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V1.0.2.7
V2.0.10: New commands:
CALCULATE:...
For additional information concerning syntax elements and returned values refer to
Conventions and General Information
.
FETCh:CDMA:MEAS<i>:MEValuation:TRACe:CDE:ISIGnal:LIMit?
FETCh:CDMA:MEAS<i>:MEValuation:TRACe:CDE:QSIGnal:LIMit?
Return limit check results for the code domain error (CDE) I-Signal and Q-Signal bar
graphs.
Return values:
<Reliability>
<QSigLimit0> ...
<QSigLimit(SF-1)>
Return the exceeded limits as float values.
The number of results depends on the selected spreading factor:
SF=16, 32, 64.
Example:
See
Multi Evaluation: Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V2.0.10
FETCh:CDMA:MEAS<i>:MEValuation:TRACe:CDE:ISIGnal:STATe?
FETCh:CDMA:MEAS<i>:MEValuation:TRACe:CDE:QSIGnal:STATe?
Return the states of the code domain error (CDE) I-Signal and Q-Signal bar graphs.
Return values:
<Reliability>
Command Reference
深圳德标仪器