CDMA2000 Signaling
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
706
User Manual 1173.9511.02 ─ 11
Manual operation:
See
SENSe:CDMA:SIGN<i>:RXQuality:RLP:BLANk?
Queries number of RLP frames with no encapsulated data.
Return values:
<RX>
Number of RLP frames received in the last update period
Range:
0 to 9.6
<RX_Total>
Total number of RLP frames received during the PPP connec-
tion
Range:
0 to 9.6
<TX>
Number of RLP frames transmitted in the last update period
Range:
0 to 9.6
<TX_Total>
Total number of RLP frames transmitted during the PPP connec-
tion
Range:
0 to 9.6
Example:
See
Usage:
Query only
Firmware/Software:
V3.0.20
Manual operation:
See
SENSe:CDMA:SIGN<i>:RXQuality:RLP:INValid?
Queries number of RLP frames evaluated by RLP validity check as invalid.
Return values:
<RX>
Number of RLP frames received in the last update period
Range:
0 to 9.6
<RX_Total>
Total number of RLP frames received during the PPP connec-
tion
Range:
0 to 9.6
<TX>
Number of RLP frames transmitted in the last update period
Range:
0 to 9.6
<TX_Total>
Total number of RLP frames transmitted during the PPP connec-
tion
Range:
0 to 9.6
Example:
See
Usage:
Query only
Firmware/Software:
V3.0.20
Manual operation:
See
Command Reference
深圳德标仪器