1xEV-DO Signaling
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
104
User Manual 1173.9511.02 ─ 11
Fig. 2-50: Neighbor cell settings
......................................................................................... 104
............................................................................................... 104
RxLevMinEUTRACommon
Configures the low reselection threshold value for LTE neighbor cells. The resulting
threshold value in dBm is displayed for information (-44 - RxLevMinEUTRACommon).
Option R&S CMW-KS890 is required.
Remote command:
ThreshServing
Specifies the limit for pilot power level below which the AT triggers cell reselection to a
neighbor cell in the candidate set. The resulting threshold value in dB is displayed for
information (-ThreshServing / 2).
Option R&S CMW-KS890 is required.
Remote command:
Max Reselection Timer
Specifies the maximum time for the access terminal to execute the cell reselection.
The resulting time value in s is displayed for information (2
MaxReselectionTimer
).
Option R&S CMW-KS890 is required.
Remote command:
Configuration
To configure the neighbor cell entries, press the "Edit..." button. Only the enabled
entries are broadcast.
GUI Reference
深圳德标仪器