1xEV-DO Measurements
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
352
User Manual 1173.9511.02 ─ 11
CONFigure:EVDO:MEAS<i>:MEValuation:IQLCheck
.........................................................352
CONFigure:EVDO:MEAS<i>:MEValuation:LIMit:CDP
........................................................ 352
CONFigure:EVDO:MEAS<i>:MEValuation:LIMit:CDE
........................................................ 352
CONFigure:EVDO:MEAS<i>:MEValuation:LIMit:CP
...........................................................353
CONFigure:EVDO:MEAS<i>:MEValuation:LIMit:DWCP
..................................................... 353
CONFigure:EVDO:MEAS<i>:MEValuation:IQLCheck
<IQLeakageCheck>
Enables or disables the CDP I/Q leakage check.
Parameters:
<IQLeakageCheck> OFF | ON
ON:
enable check
OFF:
disable check
*RST:
OFF
Example:
See
Firmware/Software:
V1.0.4.11
Manual operation:
See
CONFigure:EVDO:MEAS<i>:MEValuation:LIMit:CDP
<CDPUserLimit>
Defines an upper limit for the code domain power of inactive channels.
Parameters:
<CDPUserLimit>
Range:
-70 dB to 0 dB
*RST:
-23 dB
Default unit: dB
Example:
See
Firmware/Software:
V1.0.3.3
Manual operation:
See
CONFigure:EVDO:MEAS<i>:MEValuation:LIMit:CDE
<CDEUserLimit>
Defines an upper limit for the code domain error.
Parameters:
<CDEUserLimit>
Range:
-70 dB to 0 dB
*RST:
-23 dB
Default unit: dB
Example:
See
Firmware/Software:
V1.0.3.3
Manual operation:
See
Command Reference
深圳德标仪器
135-1095-0799