1xEV-DO Measurements
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
382
User Manual 1173.9511.02 ─ 11
Firmware/Software:
V2.0.20
V3.0.11 Frequency unit changed from MHz to Hz
For additional information concerning syntax elements and returned values refer to
Conventions and General Information
.
3.5.4.20
Modulation Results (Single Values)
The following commands return the results of the modulation multi evaluation measure-
ment.
FETCh:EVDO:MEAS<i>:MEValuation:MODulation:CURRent?
FETCh:EVDO:MEAS<i>:MEValuation:MODulation:AVERage?
FETCh:EVDO:MEAS<i>:MEValuation:MODulation:MINimum?
FETCh:EVDO:MEAS<i>:MEValuation:MODulation:MAXimum?
FETCh:EVDO:MEAS<i>:MEValuation:MODulation:SDEViation?
READ:EVDO:MEAS<i>:MEValuation:MODulation:CURRent?
READ:EVDO:MEAS<i>:MEValuation:MODulation:AVERage?
READ:EVDO:MEAS<i>:MEValuation:MODulation:MINimum?
READ:EVDO:MEAS<i>:MEValuation:MODulation:MAXimum?
READ:EVDO:MEAS<i>:MEValuation:MODulation:SDEViation?
CALCulate:EVDO:MEAS<i>:MEValuation:MODulation:CURRent?
CALCulate:EVDO:MEAS<i>:MEValuation:MODulation:AVERage?
CALCulate:EVDO:MEAS<i>:MEValuation:MODulation:MINimum?
CALCulate:EVDO:MEAS<i>:MEValuation:MODulation:MAXimum?
CALCulate:EVDO:MEAS<i>:MEValuation:MODulation:SDEViation?
Return the current, average, minimum, maximum and standard deviation modulation
single value results.
The values described below are returned by
FETCh
and
READ
commands.
CALCulate
commands return limit check results instead, one value for each result listed below.
The ranges indicated below apply to all results except standard deviation results. The
minimum for standard deviation results equals 0. The maximum equals the width of the
indicated range divided by two. Exceptions are explicitly stated.
The number to the left of each result parameter is provided for easy identification of the
parameter position within the result array.
Return values:
<1_Reliability>
<2_EVMRMS>
<3_EVMPeak>
Error vector magnitude RMS and peak value
Range:
0 % to 100 %
Default unit: %
<4_MErrRMS>
Magnitude error RMS value
Range:
0 % to 100 %
Default unit: %