1xEV-DO Measurements
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
298
User Manual 1173.9511.02 ─ 11
3.3.15 OLTR Measurement Results
The results of the 1xEV-DO OLTR measurement are displayed in several different
views; see detailed description in section
chapter 3.2.9.4, "OLTR: Results"
The OLTR measurement provides a detailed view for each measurement sequence.
An OLTR limit violation is indicated underneath the graphs:
Fig. 3-32: OLTR: results with limit violation
An overview is available in case more than one measurement sequence is configured: