1xEV-DO Measurements
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
276
User Manual 1173.9511.02 ─ 11
(or half slots) are rejected. The ratio is evaluated in a moving window of 1000 slots (or
half slots). Changing from a non-matching signal configuration to a matching configura-
tion results in a linear increase of the ratio from 0 % to 100%.
3.3 GUI Reference
The following sections provide detailed reference information on the parameters of the
1xEV-DO multi evaluation and open loop time response (OLTR) measurements. The
GUI reference is structured as follows.
............................................................................................276
Signal Routing and Analyzer Settings
...................................................................277
Multi Evaluation: Carrier Configuration
................................................................. 281
Multi Evaluation: Code Channel Filter
...................................................................283
Multi Evaluation: Code Channel Data Modulation
................................................ 284
Multi Evaluation: Measurement Control
................................................................ 284
Multi Evaluation: Limit Settings
............................................................................. 290
................................................................................................292
Multi Evaluation Measurement Results
.................................................................292
................................................................................295
................................................................................................297
.................................................................................298
Additional Softkeys and Hotkeys
...........................................................................299
3.3.1 Measurement Control
To be able to start any of the comprised TX measurements ("Multi Evaluation" or
"OLTR"), check the corresponding measurement via "Display" > "Select View".
........................................................................................... 277
.........................................................................................277
Select View (Hotkey)
To focus on a particular measurement (i.e. to activate its tab) and to select a view
(within this tab), use the softkey-hotkey combination "Display" > "Select View":
●
the radio buttons select the measurement
●
the combo boxes select the view to be activated
GUI Reference