1xEV-DO Signaling
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
151
User Manual 1173.9511.02 ─ 11
Parameters:
<ActiveOnAN>
OFF | ON
When set to OFF, the related carrier is physically disabled on
the handoff destination cell.
Note that pilot 0 cannot be turned OFF.
*RST:
ON
Example:
See
Firmware/Software:
V2.1.20
Options:
R&S CMW-KS881
Manual operation:
See
CONFigure:EVDO:SIGN<i>:HANDoff:NETWork:PILot:AT:ASSigned
<AssignedToAT>
Sets/gets the assignment state of a pilot in the handoff destination cell. Assigning a
pilot to the AT adds the pilot to the AT's active set in the destination cell.
The related pilot has to be pre-selected using the
command.
Parameters:
<AssignedToAT>
OFF | ON
A pilot can only be assigned to the AT if it is activated on the
destination cell (see
Note that pilot 0 cannot be unassigned.
*RST:
ON
Example:
See
Firmware/Software:
V2.1.20
Options:
R&S CMW-KS881
Manual operation:
See
CALL:EVDO:SIGN<i>:HANDoff:STARt
Initiates a handoff to the previously configured destination cell.
After the handoff, the destination cell settings replace the current cell settings.
Example:
See
Usage:
Event
Firmware/Software:
V1.0.15.0
Mode:
Connection state CONN
Manual operation:
See
Command Reference
深圳德标仪器