CDMA2000 Signaling
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
681
User Manual 1173.9511.02 ─ 11
Firmware/Software:
V.1.0.15
Options:
R&S CMW-KS810
Manual operation:
See
CONFigure:CDMA:SIGN<i>:NETWork:APRobes:IOFFset
<InitialOffset>
Specifies the initial power offset for access probes (INIT_PWR) parameter in the
Access Parameters Message.
Parameters:
<InitialOffset>
Range:
-16 dB to 15 dB
Increment: 1 dB
*RST:
0 dB
Default unit: dB
Example:
See
Firmware/Software:
V1.0.15.0
Options:
R&S CMW-KS810
Manual operation:
See
CONFigure:CDMA:SIGN<i>:NETWork:APRobes:PINCrement
<ProbeIncrement>
Defines the step size of power increases (PWR_STEP) between consecutive access
probes.
Parameters:
<ProbeIncrement>
Range:
0 dB to 7 dB
Increment: 0.5 dB
*RST:
3 dB
Default unit: dB
Example:
See
Firmware/Software:
V1.0.15.0
Options:
R&S CMW-KS810
Manual operation:
See
CONFigure:CDMA:SIGN<i>:NETWork:APRobes:PPSequence
<ProbPerSequence>
Defines the maximum number of access probes (NUM_STEP) contained in a single
access probe sequence.
Parameters:
<ProbPerSequence> Range:
1 to 16
*RST:
16
Example:
See
Firmware/Software:
V1.0.15.0
Command Reference