1xEV-DO Signaling
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
149
User Manual 1173.9511.02 ─ 11
Parameters:
<Channel>
The reset value and the range of possible channels depend on
the selected band class; for an overview see
on page 27. The values below are for band
class BC0 (US Cellular).
Range:
1 to 799, 991 to 1323
*RST:
283
Example:
See
Firmware/Software:
V1.0.15.0
Mode:
connection state "CONNected"
Manual operation:
See
CONFigure:EVDO:SIGN<i>:HANDoff:CARRier:CHANnel
<CarrierChannel>
Sets/gets the channel for a carrier in the handoff destination cell.
The related carrier has to be pre-selected using the
command.
Parameters:
<CarrierChannel>
The range of possible channels depends on the destination
cell's selected band class. For an overview see
on page 27. The values below are for band
class BC0 (US Cellular).
Range:
1 to 799, 991 to 1323
*RST:
183
Example:
See
Firmware/Software:
V2.1.20: Channel offset specification (relative to carrier 0) for
carriers 1 and 2
V3.0.10: Direct channel assignment for carriers 1 and 2
CONFigure:EVDO:SIGN<i>:HANDoff:CARRier:FLFRequency?
Gets the forward link frequency for a carrier in the handoff destination cell.
The related carrier has to be pre-selected using the
command.
This frequency is determined by the handoff destination cell's main carrier channel and
the related carrier's channel offset.
Return values:
<CFwdLinkFreq>
Range:
100E+6 Hz to 6.1E+9 Hz
Example:
See
Usage:
Query only
Firmware/Software:
V2.1.20
Command Reference
深圳德标仪器
135-1095-0799