CDMA2000 Signaling
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
652
User Manual 1173.9511.02 ─ 11
Parameters:
<PowerCtrlBits>
AUTO | RTESt | AUP | ADOWn | HOLD | PATTern
AUTO
: Active closed loop power control: The R&S
CMW sends
the PCB needed to control the MS transmitter output power to
the expected value.
RTES
: Range test: The R&S
CMW sends a sequence of 128 up
power bits (= 8 frames) followed by a sequence of 128 down
power bits.
AUP
: All UP: Sends only
0
as power control bits.
ADOW
: All DOWn. Sends only
1
as power control bits.
HOLD
: Sends alternating
0
/
1
power control bits. Can be used to
keep the current power level constant.
PATT
: Sends the user specific segment bits executed by
*RST:
AUTO
Example:
See
Specifying General Signaling Settings
Firmware/Software:
V1.0.15.0
V3.2.60: added "PATTern"
Manual operation:
See
CONFigure:CDMA:SIGN<i>:RPControl:SSIZe
<StepSize>
Sets the power step size that the MS is to use for power control. The step size is the
nominal change of the MS transmit power per single power control bit.
Parameters:
<StepSize>
Range:
0.25 dB | 0.5 dB | 1 dB
*RST:
1 dB
Default unit: dB
Example:
See
Specifying General Signaling Settings
Firmware/Software:
V1.0.15.0
V2.1.20: Step Size 0.25 dB supported
Options:
R&S CMW-KS810
Manual operation:
See
CONFigure:CDMA:SIGN<i>:RPControl:REPetition
<Repetition>
Specifies the repetition mode of the pattern execution.
Parameters:
<Repetition>
SINGleshot | CONTinuous
SINGleshot
: the pattern execution is stopped after a single-shot
CONTinuous
: the pattern execution is repeated continuously
and stopped by the
Command Reference