1xEV-DO Measurements
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
393
User Manual 1173.9511.02 ─ 11
<16_WavQualMaxP> Waveform quality at maximum power.
Range:
0 to 1
<17_WavQualMinP> Waveform quality at minimum power.
Range:
0 to 1
<18_OutOfTolCount> Out of tolerance result, i.e. percentage of measurement inter-
vals of the statistic count (see
limits, see
.
Range:
0 % to 100 %
Default unit: %
<19_CurStatCount> Number of evaluated valid slots in this segment.
Range:
0 to 1000
Example:
See
Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V2.0.20
Options:
R&S CMW-KM012
For additional information concerning syntax elements and returned values refer to
Conventions and General Information
.
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:SEGMent<no>:CP:CURRent?
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:SEGMent<no>:CP:AVERage?
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:SEGMent<no>:CP:MINimum?
CALCulate:EVDO:MEAS<i>:MEValuation:LIST:SEGMent<no>:CP:MAXimum?
FETCh:EVDO:MEAS<i>:MEValuation:LIST:SEGMent<no>:CP:CURRent?
FETCh:EVDO:MEAS<i>:MEValuation:LIST:SEGMent<no>:CP:AVERage?
FETCh:EVDO:MEAS<i>:MEValuation:LIST:SEGMent<no>:CP:MINimum?
FETCh:EVDO:MEAS<i>:MEValuation:LIST:SEGMent<no>:CP:MAXimum?
Returns Channel Power (CP) results for the segment <no> in list mode. To define the
statistical length for
AVERage
,
MAXimum
,
MINimum
calculation and enable the calcula-
tion of the results use the command
.
The number to the left of each result parameter is provided for easy identification of the
parameter position within the result array.
The values described below are returned by
FETCh
commands.
CALCulate
com-
mands return limit check results instead, one value for each result listed below.
Suffix:
<no>
.
1..200
The segment number must not exceed the total number of seg-
ments measured.