CONFigure:EVDO:MEAS<i>:MEValuation:LIST:SEGMent<no>:MODulation
<StatisticLength>, <EnableEVM>, <EnableMagError>, <EnablePhaseErr>,
<EnableWaveQual>, <EnableIQError>, <EnableChPow>, <EnableDWCP>,
<EnableWBNBPow>, <EnableFreqErr>
Defines the statistical length for
AVERage
,
MAXimum
,
MINimum
and
SDEViation
cal-
culation and enables the calculation of the different modulation results in segment
<no>; see
.
Suffix:
<no>
.
1..200
The segment number must not exceed the total number of seg-
ments measured.
Parameters:
<StatisticLength>
The statistical length is limited by the number of steps in the
segment which is defined by
*RST:
1
<EnableEVM>
OFF | ON
OFF:
Disable measurement.
ON:
Enable measurement of EVM.
*RST:
OFF
<EnableMagError>
OFF | ON
Disable or enable measurement of magnitude error.
*RST:
OFF
<EnablePhaseErr>
OFF | ON
Disable or enable measurement of phase error.
*RST:
OFF
<EnableWaveQual> OFF | ON
Disable or enable measurement of waveform quality.
*RST:
OFF
<EnableIQError>
OFF | ON
Disable or enable measurement of I/Q origin offset and imbal-
ance.
*RST:
OFF
<EnableChPow>
OFF | ON
Disable or enable measurement of channel power.
*RST:
OFF
<EnableDWCP>
OFF | ON
Disable or enable measurement of Data Walsh Code channel
power.
*RST:
OFF