1xEV-DO Signaling
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
177
User Manual 1173.9511.02 ─ 11
CONFigure:EVDO:SIGN<i>:RPControl:SEGMent<no>:LENGth
<SegmentLength>
Sets the length of the segment of the user specific power control bits.
Suffix:
<no>
.
1..4
Segment number
Parameters:
<SegmentLength>
Segment length
Range:
0 bits to 128 bits
Default unit: bit
Example:
See
Configuring Reverse Power Control Setup
Firmware/Software:
V3.2.80
Options:
R&S CMW-K890
Manual operation:
See
CONFigure:EVDO:SIGN<i>:RPControl:RUN
<RunSequenceState>
Starts and in continuous mode also stops the execution of the user specific pattern.
Parameters:
<RunSequenceState>OFF | ON
Example:
See
Configuring Reverse Power Control Setup
Firmware/Software:
V3.2.80
Options:
R&S CMW-K890
Manual operation:
See
2.6.6.8
Time
The following commands configure the CDMA System Time Settings. Note that they
can only be modified in the Signal-Off state.
CONFigure:EVDO:SIGN<i>:SYSTem:TSOurce
.................................................................177
CONFigure:EVDO:SIGN<i>:SYSTem:DATE
..................................................................... 178
CONFigure:EVDO:SIGN<i>:SYSTem:TIME
...................................................................... 178
CONFigure:EVDO:SIGN<i>:SYSTem:LTOFfset
................................................................ 179
CONFigure:EVDO:SIGN<i>:SYSTem:LTOFfset:HEX?
.......................................................179
CONFigure:EVDO:SIGN<i>:SYSTem:LSEConds
.............................................................. 180
CONFigure:EVDO:SIGN<i>:SYSTem:SYNC
.....................................................................180
CONFigure:EVDO:SIGN<i>:SYSTem:ATIMe
.................................................................... 180
CONFigure:EVDO:SIGN<i>:SYSTem:TSOurce
<SourceTime>
Queries/sets the time source for the derivation of the CMDA system time.
Command Reference