1xEV-DO Measurements
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
396
User Manual 1173.9511.02 ─ 11
Suffix:
<no>
.
1..200
The segment number must not exceed the total number of seg-
ments measured.
Return values:
<1_Reliabiltiy>
Conventions and General Information
. In list mode, a zero relia-
bility indicator indicates that the results in all measured seg-
ments are valid. A non-zero value indicates that an error occur-
red in at least one of the measured segments.
<2_SegReliability>
0 | 3 | 4 | 8
The segment reliability indicates whether one of the following
exceptions occurred in this segment:
0:
No error
3:
Signal overflow
4:
Signal low
8:
Synchronization error
If a combination of exceptions occurs, the most severe error is
indicated.
<3_PowOffsetM9>, ...
, <12_PowOffsetM0>,
<13_PowCarrier>,
<14_PowOffsetP0>,
...
,<23_PowOffsetP9>,
Returns the adjacent channel power measured at a series of fre-
quencies.
The frequencies are determined by the offset values defined via
the commands
ues are considered (irrespective of their activation status).
The power offsets <PowOffsetPn> (<PowOffsetMn>) refer to the
average power at the carrier frequency plus (minus) the fre-
quency offset value number n.
Range:
-100 dB to 20 dB
Default unit: dB
<24_ATPowerWide> Access terminal power, measured with the wideband filter.
Range:
-100 dBm to 50 dBm
Default unit: dBm
<25_ATPwNarrow>
Access terminal power, measured with a filter bandwidth of 1.23
MHz.
Range:
-100 dBm to 50 dBm
Default unit: dBm
<26_OutOfTolCount> Out of tolerance result, i.e. percentage of measurement inter-
vals of the statistic count (see
limits, see
.
Range:
0 % to 100 %
Default unit: %
Command Reference