1xEV-DO Measurements
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
304
User Manual 1173.9511.02 ─ 11
F100k,F100k,F100k,F100k
CONFigure:EVDO:MEAS:MEValuation:ACP:EXTended:RBW:LOWer F100k,F100k,F100k,
F100k,F30K,F30K,F30K,F30K,F30K,F30K,F30K,F30K,F30K,F30K,F30K,
F30K,F30K,F30K,F30K,F30K
CONFigure:EVDO:MEAS:MEValuation:ACP:RBW:UPPer F100k,F100k,F100k,F100k,F30K,
F30K,F30K,F30K,F30K,F30K
CONFigure:EVDO:MEAS:MEValuation:ACP:EXTended:RBW:UPPer F100k,F100k,F100k,
F100k,F30K,F30K,F30K,F30K,F30K,F30K,F30K,F30K,F30K,F30K,F30K,
F30K,F30K,F30K,F30K,F30K
// *************************************************************************
// Specify modulation settings:
// Measurement over 20 statistics cycles
// *************************************************************************
CONFigure:EVDO:MEAS:MEValuation:SCOunt:MODulation 20
// *************************************************************************
// Specify spectrum settings:
// Measurement over 20 statistics cycles
// *************************************************************************
CONFigure:EVDO:MEAS:MEValuation:SCOunt:SPECtrum 20
3.4.1.4
Multi Evaluation Limits
// *************************************************************************
// Define modulation limits
// *************************************************************************
CONFigure:EVDO:MEAS:MEValuation:LIMit:MERR:RMS 20
CONFigure:EVDO:MEAS:MEValuation:LIMit:MERR:PEAK OFF
CONFigure:EVDO:MEAS:MEValuation:LIMit:EVM:RMS 20
CONFigure:EVDO:MEAS:MEValuation:LIMit:EVM:PEAK 40
CONFigure:EVDO:MEAS:MEValuation:LIMit:PERR:RMS 20
CONFigure:EVDO:MEAS:MEValuation:LIMit:PERR:PEAK OFF
CONFigure:EVDO:MEAS:MEValuation:LIMit:IQOFfset -20
CONFigure:EVDO:MEAS:MEValuation:LIMit:IQIMbalance ON
CONFigure:EVDO:MEAS:MEValuation:LIMit:CFERror 150
CONFigure:EVDO:MEAS:MEValuation:LIMit:TTERror 1
CONFigure:EVDO:MEAS:MEValuation:LIMit:WQUality 0.95
CONFigure:EVDO:MEAS:MEValuation:LIMit:MAXPower -5
CONFigure:EVDO:MEAS:MEValuation:LIMit:MINPower -60
// *************************************************************************
// Define the following limits: code domain power, code domain
// error, channel power, data Walsh code channel power,
// activate the I/Q cross check.
// *************************************************************************
CONFigure:EVDO:MEAS:MEValuation:LIMit:CDP -20
CONFigure:EVDO:MEAS:MEValuation:LIMit:CDE -20
CONFigure:EVDO:MEAS:MEValuation:LIMit:CP -10