Alarm Setup Screen
Alarm Setup Screen
LASAIR II Operator’s Manual
LASAIR II Operator’s Manual
Page
Page
5-13
5-13
Printing on Alarm
Printing on Alarm
This feature automatically prints one of the following error reports when an
This feature automatically prints one of the following error reports when an
alarm occurs:
alarm occurs:
Print-on-Alarm can be enabled or disabled on
Print-on-Alarm can be enabled or disabled on the LASAIR II’s Alarm Setup
the LASAIR II’s Alarm Setup
Screen or on t
Screen or on the HTML page. See
he HTML page. See “Printout and Legend” on
“Printout and Legend” on page
page 8-21.
8-21.
T
To enable
o enable Print-on Alarm:
Print-on Alarm:
1
1
From the Main Display Screen, open the Sampling Setup Screen by
From the Main Display Screen, open the Sampling Setup Screen by
pressing the Main Setup icon softkey
pressing the Main Setup icon softkey..
2
2
From the Main Setup Screen, open the Alarms Setup Screen by pressing
From the Main Setup Screen, open the Alarms Setup Screen by pressing
the Alarms
the Alarms softkey
softkey..
3
3
Enable the edit mode by
Enable the edit mode by pressing the Enter softkey.
pressing the Enter softkey.
4
4
If necessary
If necessary, press the Enter softkey to activate the a
, press the Enter softkey to activate the alarm function.
larm function.
5
5
Navigate to the “printer” icon
Navigate to the “printer” icon
and press the Enter softkey
and press the Enter softkey. The icon will
. The icon will
appear to be depressed below the surface of the LCD display.
appear to be depressed below the surface of the LCD display.
6
6
Press
Press the
the Return
Return icon
icon softkey
softkey
to
to exit
exit the
the Alarm
Alarm Setup
Setup Screen.
Screen.
To Edit the Alarm Setup:
To Edit the Alarm Setup:
1
1
press the Enter button.
press the Enter button.
2
2
Use the tab and back tab keys to move from the Particle Alarm Setup Screen and
Use the tab and back tab keys to move from the Particle Alarm Setup Screen and
the Analog Alarm Setup Screen and to move to the major areas within each
the Analog Alarm Setup Screen and to move to the major areas within each
setup screen.
setup screen.
3
3
Use the Arrow keys to move within an
Use the Arrow keys to move within an alarm matrix. Use the Enter key to
alarm matrix. Use the Enter key to
initiate and to confirm changes.
initiate and to confirm changes.
To move back and forth from Particle Alarms and Analog Alarms:
To move back and forth from Particle Alarms and Analog Alarms:
press the “T
press the “Tab softkey” when you are out of edit mode.
ab softkey” when you are out of edit mode.
•• F
Fllo
ow
w E
Errrro
orr
•• P
Paarrttiicclle
e A
Allaarrm
m
•• L
Laasseer
r E
Errrro
orr
•• A
An
naallo
og
g A
Allaarrm
m