11.6.44 Error 47: Functional safety, common error
11.6.44.1 Error 47-0 (emergency code 6100h)
Cause: Unknown error in functional safety interface detected
Suggested steps:
Acknowledge error, if the error occurs again, reset device
This is probably a software
issue.
l
Please try to switch to a different version of
device firmware.
l
Save your dataset and reset the axis module to
factory setting. See if the error persists, or if it
comes with activating a certain feature.
This is possibly a hardware
issue
If other measures fail to solve the problem, please
replace the servo drive.
11.6.44.2 Error 47-1 (emergency code 6100h)
Cause: Communication error to safety system detected
Suggested steps:
Acknowledge error, if the error occurs again, reset device
An error occurred in the
communication to the safety
system.
l
Please acknowledge the error.
l
If the error occurs again please restart the
application (24V reset).
This is probably a software
issue.
l
Please try to switch to a different version of
device firmware.
l
Save your dataset and reset the axis module to
factory setting. See if the error persists, or if it
comes with activating a certain feature.
MOOG
ID No.: CB40859-001 Date: 11/2020
MSD Servo Drive - Device Help
426
11 Alarms & warnings
11.6.44.3 Error 47-2 (emergency code 6100h)
Cause: Error while requesting data from safety system
Suggested steps:
Acknowledge error, if the error occurs again, reset device
An error occurred in the
communication to the safety
system.
l
Please acknowledge the error.
l
If the error occurs again please restart the
application (24V reset).
This is probably a software
issue.
l
Please try to switch to a different version of
device firmware.
l
Save your dataset and reset the axis module to
factory setting. See if the error persists, or if it
comes with activating a certain feature.
11.6.44.4 Error 47-3 (emergency code 6100h)
Cause: Download of safe PLC application file failed
Suggested steps:
Acknowledge error and try download again
An error occured at the up-
or download of the safety
programm.
l
Please check the security program.
l
Please check the connection settings of your
safety system in Safe PLC.
l
Please reload or download the safety program
again.