ID
Index Name
Unit Description
429
0
ISA00_gain
Gain scaling for input ISA00
429
1
ISA01_gain
Gain scaling for input ISA01
429
2
ISA00_limMin
Minimum value for input ISA00
429
3
ISA01_limMin
Minimum value for input ISA01
429
4
ISA00_limMax
Maximum value for input ISA00
429
5
ISA01_limMax
Maximum value for input ISA01
665
0
DV_CAL_IsaType
Analog inputs: Switch between current/voltage
input
Table 9.11: “Analog inputs” parameters (continue)
9.4.2 Function selectors
Before using the analog inputs, they are normally associated with a special device
functionality for analog inputs. The corresponding function selectors also make it
possible to select a special digital functionality instead.
ID
Index Name / Setting
Unit Description
109-110
0
MPRO_INPUT_FS_
ISA0x
“Analog inputs” “function selectors”
PRC_REF (-14)
Process controller reference value
PRC_ACT (-13)
Process controller actual value
ENC_ANA (-12)
Analog encoder (on channel 4)
TWIN_SCALE (-11)
TWIN position scaling
HYD_Q_ACT (-10)
Hydraulic actual flow (software specific)
HYD_P_ACT2 (-9)
Hydraulic actual pressure on 2nd sensor
(software specific)
HYD_Q_REF (-8)
Hydraulic reference flow (software specific)
HYD_P_ACT (-7)
Hydraulic actual pressure (software specific)
HYD_P_REF (-6)
Hydraulic reference pressure (software specific)
VFC_REF_SCALE (-5)
VFC reference scaling 0-100% (software
specific)
TLIM (-4)
Analog torque limit 0-100%
OVR (-3)
Speed override 0-100% at positioning
Table 9.12: “Analog inputs” function selectors
MOOG
ID No.: CB40859-001 Date: 11/2020
MSD Servo Drive - Device Help
304
9 Inputs/Outputs settings
ID
Index Name / Setting
Unit Description
REFV (-2)
Analog reference
(-1)
Not defined
Off (0)
No function
START (1)
Start motor control
INV (2)
Inverse reference value
STOP (3)
Execute quickstop
HALT (4)
Disable feed
LCW (5)
Limit switch positive direction
LCCW (6)
Limit switch negative direction
INCH_P (7)
Jog Positive
INCH_N (8)
Jog Negative
HOMST (9)
Start homing
HOMSW (10)
Reference switch
E_EXT (11)
External error
WARN (12)
External warning
RSERR (13)
Reset alarm
MAN (14)
Switch control location selector
(15)
Not defined
PLC (16)
Used in PLC
PLC_IR (17)
PLC interrupt
MP_UP (18)
Motor potentiometer Negative
MP_DOWN (19)
Motor potentiometer Positive
(20) - (20)
Not defined
TBEN (21)
Enable selected table index
TBTEA (22)
Write actual position into selected table index
TAB0 (23)
Binary table index 2^0
TAB1 (24)
Binary table index 2^1
TAB2 (25)
Binary table index 2^2
TAB3 (26)
Binary table index 2^3
EGEAR (27)
Start / stop Egear
REFANAEN (28)
Enable analog reference
(29)
Not defined
(30)
Not defined