11.6.25.8 Error 24-8 (emergency code 7307h)
Cause: Channel 3 Initialization, EndDat 2.1: CRC error, position data from encoder
Suggested steps:
The transmission is probably disturbed. Please check the wiring to the encoder.
Initialization encoder
channel 3
l
Error during the initialization routines of
encoder channel 3.
l
In any case look at init outputs in the message
window of the
Moog D
RIVE
A
DMINISTRATOR
5 .
l
The most common cause of error is the wiring
to the encoder.
11.6.25.9 Error 24-9 (emergency code 7307h)
Cause: Channel 3 Initialization, EndDat 2.1: CRC error, parameter data from
encoder
Suggested steps:
The transmission is probably disturbed. Please check the wiring to the encoder.
Initialization encoder
channel 3
l
Error during the initialization routines of
encoder channel 3.
l
In any case look at init outputs in the message
window of the
Moog D
RIVE
A
DMINISTRATOR
5 .
l
The most common cause of error is the wiring
to the encoder.
MOOG
ID No.: CB40859-001 Date: 11/2020
MSD Servo Drive - Device Help
392
11 Alarms & warnings
11.6.25.10 Error 24-10 (emergency code 7307h)
Cause: Channel 3 Initialization, EndDat 2.1: not allowed write operation to write
protected cells or protection cells of the encoder
Suggested steps:
No further information available. Please contact your service provider.
Initialization encoder
channel
l
This is probably a software problem!
l
In any case look at init outputs in the message
window of the
Moog D
RIVE
A
DMINISTRATOR
5 .
11.6.25.11 Error 24-15 (emergency code 7307h)
Cause: Channel 3 Initialization, SSI: 'MultiTurn' from parameter (573) ENC_CH1_
MultiT
Suggested steps:
Change the input of the multiturn bits of the parameter.
Initialization encoder
channel
l
This is probably a problem of the
parameterization!
l
In any case look at init outputs in the message
window of the
Moog D
RIVE
A
DMINISTRATOR
5 .