Step
Subject area
Action
Instruction
Rotary motor
Linear motor
7.
l
Motor phase test
l
Determine encoder offset
l
Determine mass inertia
Automatic tests
8.
Open manual mode window
l
Control type V/Hz (open loop) operation
l
Move motor at low speed
l
Check direction
Motor test in manual mode without
intervention of a higher-level PLC
9.
l
Optimize current controller (test signal generator). When there is a motor
data set the current of the test signal generator is set automatically.
l
Optimizing the speed controller
l
Determine mass inertia [J] (basic settings)
l
Set speed filter:
P 0351 CON_SCALC_TF = (0,6 ms)
Recommendation, Sin/Cos encoder 0.2 ms - 0.6 ms
Recommendation, resolver: 1 ms - 2 ms
Adjust control parameters to suit the mechanism (set stiffness).
Controller setting
l
Current Controller
l
Speed controller
l
Position controller
10.
Settings:
l
Units
l
Reference source
l
Reference processing
l
Stop ramps
l
Homing method
Motion profile setting
Table 3.1: Instructions for the commissioning wizard (continue)
MOOG
ID No.: CB40859-001 Date: 11/2020
MSD Servo Drive - Device Help
20
3 Initial commissioning