11.6.25.20 Error 24-44 (emergency code 7307h)
Cause: Channel 3 Initialization, LinMot: common error
Suggested steps:
Please note the extended information of the error message
Initialization encoder
channel 3
l
Error during the initialization routines of
encoder channel 3.
l
In any case look at init outputs in the message
window of the
Moog D
RIVE
A
DMINISTRATOR
5 .
l
The most common cause of error is the wiring
to the encoder.
11.6.25.21 Error 24-45 (emergency code 7307h)
Cause: Channel 3 Initialization, SinCos: error, encoder monitoring
Suggested steps:
Please connect the encoder correctly.
Initialization encoder
channel 3
l
Error during the initialization routines of
encoder channel 3.
l
In any case look at init outputs in the message
window of the
Moog D
RIVE
A
DMINISTRATOR
5 .
l
The most common cause of error is the wiring
to the encoder.
MOOG
ID No.: CB40859-001 Date: 11/2020
MSD Servo Drive - Device Help
395
11 Alarms & warnings
11.6.25.22 Error 24-46 (emergency code 7307h)
Cause: Channel 3 Initialization: the internal multiturn resolution is too low to process
ENC_CH3_MTBase correctly.
Suggested steps:
Please reduce the internal position resolution to free bits for the internal multi-turn
information.
Initialization encoder
channel
l
This is probably a problem of the
parameterization!
l
In any case look at init outputs in the message
window of the
Moog D
RIVE
A
DMINISTRATOR
5 .
11.6.25.23 Error 24-47 (emergency code 7307h)
Cause: Channel 3 Initialization, EndDat22: common error
Suggested steps:
Please note the extended information of the error message
Initialization encoder
channel 3
l
Error during the initialization routines of
encoder channel 3.
l
In any case look at init outputs in the message
window of the
Moog D
RIVE
A
DMINISTRATOR
5 .
l
The most common cause of error is the wiring
to the encoder.