11.6.19.5 Error 18-5 (emergency code FF00h)
Cause: Homing: Homing method available but not defined
Suggested steps:
Homing is not available with this motion profile. Please select another homing
method.
11.6.19.6 Error 18-6 (emergency code FF00h)
Cause:
Homing: Drive not ready for homing: Error is triggered when the motor is not stopped
, or the standstill bit is not set (Standstill window).
Suggested steps:
Please stop the motor. Check the positon window parameter 746 [0] (subject area
limits).
11.6.19.7 Error 18-7 (emergency code FF00h)
Cause: Homing: Drive not ready for jog mode
Suggested steps:
Please stop the motor. Check the position window parameter 746 [0] (subject area
limits).
11.6.19.8 Error 18-8 (emergency code FF00h)
Cause: Homing: Control mode does not match homing method
Suggested steps:
Homing is only possible in position control mode.
MOOG
ID No.: CB40859-001 Date: 11/2020
MSD Servo Drive - Device Help
365
11 Alarms & warnings
11.6.19.9 Error 18-9 (emergency code FF00h)
Cause: Homing: Encoder initialization error
Suggested steps:
The homing during device start-up was not performed due to an internal error.
Please restart the application (24V reset).
An error occured at the
homing methode.
l
Please acknowledge the error.
l
Please start the homing method again.
11.6.19.10 Error 18-10 (emergency code FF00h)
Cause: Homing: Homing travel exceeded
Suggested steps:
l
The zero pulse has not been reached within the permissible distance. Please
check the zero pulse of the encoder and the parameter 169[0] for the
maximum distance.
l
Please check whether the encoder is working correctly.
11.6.19.11 Error 18-11 (emergency code FF00h)
Cause: Max. permissible tracking error on "Start control" exceeded
Suggested steps:
Reset error and start again
An error occured at the
homing methode.
l
Please acknowledge the error.
l
Please start the homing method again.