11.6.20.15 Error 19-15 (emergency code 5300h)
Cause: Error in initialization of protected memory
Suggested steps:
Switch off/on device. Please contact your service provider if this error occurs again
This is probably a software
issue.
l
Please try to switch to a different version of
device firmware.
l
Save your dataset and reset the axis module to
factory setting. See if the error persists, or if it
comes with activating a certain feature.
11.6.20.16 Error 19-16 (emergency code 5300h)
Cause: File access on device not complete
Suggested steps:
File transfer interrupted, file maybe corrupt, login and try again!
This is probably a software
issue.
l
Please try to switch to a different version of
device firmware.
l
Save your dataset and reset the axis module to
factory setting. See if the error persists, or if it
comes with activating a certain feature.
MOOG
ID No.: CB40859-001 Date: 11/2020
MSD Servo Drive - Device Help
370
11 Alarms & warnings
11.6.20.17 Error 19-17 (emergency code 5300h)
Cause: Safety-system run-up with illegal firmware!
Suggested steps:
Process firmware-update and process power on (24V) reset!
This is probably a software
issue.
l
Please try to switch to a different version of
device firmware.
l
Save your dataset and reset the axis module to
factory setting. See if the error persists, or if it
comes with activating a certain feature.
11.6.20.18 Error 19-18 (emergency code 5300h)
Cause: Firmware-update of safety-system failed!
Suggested steps:
Process power on (24V) reset!
11.6.20.19 Error 19-19 (emergency code 5300h)
Cause: System run-up with illegal FPGA firmware!
Suggested steps:
Update the FPGA with the correct firmware!
This is probably a software
issue.
l
Please try to switch to a different version of
device firmware.
l
Save your dataset and reset the axis module to
factory setting. See if the error persists, or if it
comes with activating a certain feature.