CAUTION!
Your system/motor may be damaged if put into operation in
an uncontrolled or inappropriate manner.
Improper conduct can cause damage to your system /
machine.
l
Before the “Start” step, make absolutely sure that a valid
setpoint has been entered, as the configured setpoint
will be immediately transmitted to the motor after the
motor control function starts, which may result in the
motor accelerating unexpectedly.
CAUTION!
Damage to the device as a result of incorrect operation!
Failure to exercise caution or follow proper working
procedures may result in damage to the device.
l
The mains voltage for the power supply must not be
switched on until after the available mains voltage
setting has been configured in the device firmware and
the device is restarted (in the event that the mains
voltage or the switching frequency has been changed).
2.4 Responsibility
Electronic devices are not fail-safe. The company setting up and/or operating a
complete machine or system is responsible:
l
For ensuring that the motor will be brought to a safe state if the device fails.
l
For the safety of persons and machinery.
l
For proper functional capability of the complete machine.
MOOG
ID No.: CB40859-001 Date: 11/2020
MSD Servo Drive - Device Help
16
2 Safety
l
For the risk assessment of the complete machine or system according to EN
ISO 12100:2011 and EN ISO 13849-1.
Observe the topic “Electrical equipment of machines” in EN 60204-1:2006 “Safety of
machinery”. The safety requirements defined there to be met by electrical machinery
are intended to ensure personal safety and the safety of machinery or systems.
The emergency-stop function (to IEC/EN 60204) shuts down the power supply of a
machine, which leads to uncontrolled rundown of the drives. In order to prevent
hazards, check whether the following will be required:
l
Keeping individual motors running.
l
Initiating specific safety processes.
l
Integrating an emergency stop function (emergency stop function: stopping
movement by “switching off the electrical power supply” or STO Safe Torque