• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See “
Parts listing - BladeCenter HX5
” on page 57 to determine which components are CRUs and which
components are FRUs.
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Type
Error Message
Action
Error
Processor
X
, temperature (CPU
X
OverTemp) non-recoverable [Note:
X
=1-2]
1. Make sure that the room temperature is within the
operating specifications (see “Features and
specifications” on page 4).
2. Make sure that none of the air vents on the BladeCenter
chassis and on the blade server are blocked.
3. Make sure that all of the fans on the BladeCenter chassis
are running.
4. Make sure that each bay of the BladeCenter chassis
contains either a device or a filler.
5. Make sure that the blade server is not missing any heat
sinks, DIMMs, or heat-sink fillers (see “Parts listing -
BladeCenter HX5” on page 57).
6. (Trained service technician only) Make sure that the
microprocessor heat sink is properly attached to the
microprocessor (see “Installing a microprocessor and heat
sink” on page 134).
Error
System board, interconnect (Pwr
Share Jumper) non-recoverable
1. Reseat the cap on the power sharing connector (see
“Blade server connectors - BladeCenter HX5” on page
12).
2. (Trained service technician only) Replace the system-
board assembly (see “Removing the system-board
assembly - BladeCenter HX5” on page 140 and “Installing
the system-board assembly - BladeCenter HX5” on page
142).
Error Code: 0x80090000
Information
System board, memory
(Performance Mode) disabled/
enabled
This is informational only, no action is required. The
performance mode has been enabled or disabled.
Error Code: 0x800B0100
175
Содержание BladeCenter HX5 1909
Страница 6: ...iv BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 16: ......
Страница 34: ...18 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 72: ...56 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 292: ...276 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 296: ...280 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 303: ...Taiwan Class A compliance statement Appendix B Notices 287 ...
Страница 304: ...288 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 310: ...294 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 311: ......
Страница 312: ...Part Number 46W8208 Printed in China 1P P N 46W8208 ...
Страница 313: ... 1P46W8208 ...