• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See “
Parts listing - BladeCenter HX5
” on page 57 to determine which components are CRUs and which
components are FRUs.
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Type
Error Message
Action
Error
Expansion Module
X
, Expansion
Card (BPE4_
Y
Fault) critical
Notes:
1.
X
= Module number
2.
Y
= BPE4 ID (1, 2, 3, or 4). The
max BPE4 number is 4, and
there are 2 slots in each BPE4.
Module number is based on the
configuration of the BPE4
1. Reseat the blade expansion unit (see “Removing an
expansion unit” on page 96 and “Installing an expansion
unit” on page 97).
2. Replace the blade expansion unit (see “Removing an
expansion unit” on page 96 and “Installing an expansion
unit” on page 97).
Error
Processor
X
, temperature (CPU
X
OverTemp) critical [Note:
X
=1-2]
1. Make sure that the room temperature is within the
operating specifications (see “Features and
specifications” on page 4).
2. Make sure that none of the air vents on the BladeCenter
chassis and on the blade server are blocked.
3. Make sure that all of the fans on the BladeCenter chassis
are running.
4. (Trained service technician only) Make sure that the
microprocessor heat sink is properly attached to the CPU
(see “Removing a microprocessor and heat sink” on page
130 and “Installing a microprocessor and heat sink” on
page 134).
5. (Trained service technician only) Replace the processor
(see “Removing a microprocessor and heat sink” on page
130 and “Installing a microprocessor and heat sink” on
page 134).
Error
Memory device
X
, temperature
(DIMM
X
Temp) critical [Note:
X
=1-16]
1. Make sure that the room temperature is within the
operating specifications (see “Features and
specifications” on page 4).
2. Make sure that none of the air vents on the BladeCenter
chassis and on the blade server are blocked.
3. Make sure that all of the fans on the BladeCenter chassis
are running.
4. (Trained service technician only) Make sure that the
microprocessor heat sink is properly attached to the
microprocessor (see “Installing a microprocessor and heat
sink” on page 134).
167
Содержание BladeCenter HX5 1909
Страница 6: ...iv BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 16: ......
Страница 34: ...18 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 72: ...56 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 292: ...276 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 296: ...280 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 303: ...Taiwan Class A compliance statement Appendix B Notices 287 ...
Страница 304: ...288 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 310: ...294 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 311: ......
Страница 312: ...Part Number 46W8208 Printed in China 1P P N 46W8208 ...
Страница 313: ... 1P46W8208 ...