• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See “
Parts listing - BladeCenter HX5
” on page 57 to determine which components are customer replaceable
units (CRU) and which components are field replaceable units (FRU).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
Trained service technician.
Error code
Description
Action
0068002
CMOS battery cleared.
1. Reseat the battery.
2. Clear the CMOS memory (see “System-board switches” on page
3. Replace the following components one at a time in the order shown,
restarting the server each time:
a. Battery (see “Removing the battery” on page 76 and “Installing
b. (Trained service technician only) System board. See “Removing
the system-board assembly - BladeCenter HX5” on page 140
and “Installing the system-board assembly - BladeCenter HX5”
on page 142.
2011001
PCI-X SERR
1. Use light path diagnostic LEDs to determine whether an I/O fault
LED is lit ( “Light path diagnostics LEDs” on page 207). If it is,
resolve the problem.
2. Check the system-event log to determine which I/O expansion cards
are affected.
3. Reseat all affected I/O-expansion cards.
4. If you have recently updated the device drivers for the affected I/O-
expansion cards, revert to a previous device driver.
5. Update the firmware and device drivers for the PCI device.
6. Remove the I/O-expansion cards from the system board.
7. Replace the following components one at a time in the order shown,
restarting the server each time:
a. The I/O-expansion cards
b. (Trained service technician only) System board (see “Removing
the system-board assembly - BladeCenter HX5” on page 140
and “Installing the system-board assembly - BladeCenter HX5”
on page 142).
2018001
PCI Express uncorrectable
error
1. Turn off the blade server. Then turn on the blade server and
immediately turn it off (before POST completes) four times, using
either the power button on the front of the blade server or the
advanced management module web interface.
Note:
Make sure that you turn off the blade server immediately after
starting it. Turning on the blade server and immediately turning it off
four times will cause UEFI to be start using default settings.
2. Remove the battery and reinstall the battery to clear CMOS memory
and NVRAM. The real time clock will also be reset.
3. Remove any recently installed hardware.
4. Update the server firmware through the advanced management
module web interface.
157
Содержание BladeCenter HX5 1909
Страница 6: ...iv BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 16: ......
Страница 34: ...18 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 72: ...56 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 292: ...276 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 296: ...280 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 303: ...Taiwan Class A compliance statement Appendix B Notices 287 ...
Страница 304: ...288 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 310: ...294 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 311: ......
Страница 312: ...Part Number 46W8208 Printed in China 1P P N 46W8208 ...
Страница 313: ... 1P46W8208 ...