• See “
Parts listing - BladeCenter HX5
” on page 57 to determine which components are CRUs and which
components are FRUs.
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Message
Action
System Power Good fault
1. Reseat the blade server. See “Removing the blade server from the
BladeCenter chassis” on page 66 and “Installing a blade server in
a BladeCenter chassis” on page 67.
2. Check the function of the shared BladeCenter chassis resources.
See “Solving shared BladeCenter resource problems” on page
269.
3. (Trained service technician only) Replace the system-board
assembly. See “Removing the system-board assembly -
BladeCenter HX5” on page 140 and “Installing the system-board
assembly - BladeCenter HX5” on page 142.
VRD Power Good fault
1. Reseat the blade server. See “Removing the blade server from the
BladeCenter chassis” on page 66 and “Installing a blade server in
a BladeCenter chassis” on page 67.
2. Check the function of the shared BladeCenter chassis resources.
See “Solving shared BladeCenter resource problems” on page
269.
3. (Trained service technician only) Replace the system-board
assembly. See “Removing the system-board assembly -
BladeCenter HX5” on page 140 and “Installing the system-board
assembly - BladeCenter HX5” on page 142.
System over recommended voltage for +12
V.
Informational only.
If the problem remains, complete the following steps:
1. Reseat the blade server. See “Removing the blade server from the
BladeCenter chassis” on page 66 and “Installing a blade server in
a BladeCenter chassis” on page 67.
2. Check the function of the shared BladeCenter chassis resources.
See “Solving shared BladeCenter resource problems” on page
269.
3. (Trained service technician only) Replace the system-board
assembly. See “Removing the system-board assembly -
BladeCenter HX5” on page 140 and “Installing the system-board
assembly - BladeCenter HX5” on page 142.
262
BladeCenter HX5 Blade ServerProblem Determination and Service Guide
Содержание BladeCenter HX5 1909
Страница 6: ...iv BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 16: ......
Страница 34: ...18 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 72: ...56 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 292: ...276 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 296: ...280 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 303: ...Taiwan Class A compliance statement Appendix B Notices 287 ...
Страница 304: ...288 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 310: ...294 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 311: ......
Страница 312: ...Part Number 46W8208 Printed in China 1P P N 46W8208 ...
Страница 313: ... 1P46W8208 ...