• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
• See “
Parts listing - BladeCenter HX5
” on page 57 to determine which components are CRUs and which
components are FRUs.
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Type
Error Message
Action
Error
PCI express bus 2, Expansion Card
(CIOh Exp 2 Fault) critical
1. Check the operating-system event log and the system-
event log because it might contain additional information
(see “Event logs” on page 147).
2. Update the device drivers for the CIOh expansion card.
3. Reseat the blade server in the BladeCenter chassis (see
“Removing the blade server from the BladeCenter
chassis” on page 66 and “Installing a blade server in a
BladeCenter chassis” on page 67).
4. Reseat the expansion card (see “Removing an I/O
expansion card” on page 119 and “Installing an I/O
expansion card” on page 121).
5. Replace the expansion card (see “Removing an I/O
expansion card” on page 119 and “Installing an I/O
expansion card” on page 121).
Error
PCI express bus 3, Expansion Card
(CIOv Exp Fault) critical
1. Check the operating-system event log and the system-
event log because it might contain additional information
(see “Event logs” on page 147).
2. Update the device drivers for the CIOv expansion card.
3. Reseat the blade server in the BladeCenter chassis (see
“Removing the blade server from the BladeCenter
chassis” on page 66 and “Installing a blade server in a
BladeCenter chassis” on page 67).
4. Reseat the expansion card (see “Removing an I/O
expansion card” on page 119 and “Installing an I/O
expansion card” on page 121).
5. Replace the expansion card (see “Removing an I/O
expansion card” on page 119 and “Installing an I/O
expansion card” on page 121).
Error Code: 0x80070300
Note:
Multiple events can be displayed for this error code. Be sure to read the message text to determine the
appropriate recovery actions.
172
BladeCenter HX5 Blade ServerProblem Determination and Service Guide
Содержание BladeCenter HX5 1909
Страница 6: ...iv BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 16: ......
Страница 34: ...18 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 72: ...56 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 292: ...276 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 296: ...280 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 303: ...Taiwan Class A compliance statement Appendix B Notices 287 ...
Страница 304: ...288 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 310: ...294 BladeCenter HX5 Blade ServerProblem Determination and Service Guide ...
Страница 311: ......
Страница 312: ...Part Number 46W8208 Printed in China 1P P N 46W8208 ...
Страница 313: ... 1P46W8208 ...